Circuit breaker size S00 for motor protection, CLASS 10 A-release 5.5...8 A N-release 104 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.
| Adjustment range undelayed short-circuit release | 104 A |
| Connection Style | screw-type terminals |
| Current Rating / Rated Current | 8 A |
| Degree of protection (IP) | IP20 |
| Depth | 97 mm |
| Device construction | Built-in device fixed built-in technique |
| Height | 97 mm |
| IP Rating | IP20 |
| Mounting Type | Screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Number of poles | 3 |
| Operating Period | Product Lifecycle - PM300:Active Product |
| Overload release current setting | 8 A |
| Packaging size / unit | 1 pc(s) |
| Part Depth (mm) | 97mm |
| Part Height (mm) | 97mm |
| Part Width (mm) | 45mm |
| Phase failure sensitive | Yes |
| Power loss | 9.25 W |
| Rated operating voltage | 690 V |
| Rated operation power at AC-3, 230 V | 1.5 kW |
| Rated operation power at AC-3, 400 V | 3 kW |
| Rated permanent current Iu | 8 A |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 100 kA |
| Screw Type | Diameter 5 to 6 mm / Pozidriv size 2 |
| Switch off technique | Magnetic |
| Temperature: Operating | -20°C to 60°C |
| Tightening Torque | 0.8 - 1.2 N·m |
| Type of control element | Other |
| Type of electrical connection of main circuit | Screw connection |
| Voltage Frequency Range | 50 / 60 Hz |
| Weight (g) | 346g |
| Width | 45 mm |
| With thermal overload protection | Yes |
| Country of Origin | Germany |
Complete technical specifications (PDF)
Product brochure and catalog information
Installation and operation guide
Wiring and connection guide
Compliance and certification documents
Mechanical dimensions and mounting
3D models and CAD files
Manufacturer product page and specifications
Product approvals and certificates
Environmental Product Declaration
Full specifications, datasheets and downloads
Overview, features and application examples