The AR evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit.
The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop.
The switching states of the connected safety switches can be signaled by means of monitoring outputs.
If the actuator on one of the safety switches in the switch chain is moved out of the actuating range, the AR evaluation unit opens its contacts and the corresponding monitoring output is reset.
The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts.
The system can be started either manually using a start button or automatically.
LED display | |
DIA | LED red: fault display |
OUT | LED yellow: AR chain status |
STATE | LED green: device status |
Connection cross section | 0.14 - 2.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Switching delay from state change | max. 480 ms |
Degree of contamination | 2 |
Current via feedback loop | 5 ... 8 ... 10 mA |
Permissible resistance in feedback loop | max. 600 Ω |
Output type | Semiconductor outputs, p-switching, short circuit proof |
Output voltage HIGH | UB - 20% - UB V DC |
Output voltage LOW | 0 - 1 V DC |
Output current | max. 20 mA |
Number of connectible safety switches | max. 12 |
Safety inputs | 2 (for CES-AR switch chain) |
Fuse | external (safety circuit) according to EN 60269-1 |
Utilization category | DC-13, 24 V 5 A |
Dimensions | 114 x 99 x 45 |
Connection type | plug-in screw terminals, coded |
Number of LED displays | 3 |
Ready delay | max. 8 s |
Atmospheric humidity | not condensing, max. 80 % rH |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Degree of protection | IP20 |
Ambient temperature | -20 to 55 °C |
---|---|
Material | Plastic PA6.6 |
Item designation | CES-AR-AES-12 |
Gross weight | 0,326kg |
Customs tariff number | 85364110 |
ECLASS | 27-27-24-03 Safety-related transponder switch |