Siemens

Siemens Miniature circuit breaker 230/400 V 10kA, 1-pole, B, 16A Part number 5SY4116-6

EAN / Barcode 4001869181219
Product Type Control Panel
Product Class Miniature circuit breaker (MCB)
ETIM Class Miniature circuit breaker (MCB)
Back Order
View Full Product Details on Siemens 💬 Ask an Expert - Technical Support Available

Product Description

Product Overview

The Siemens 5SY4116-6 is a miniature circuit breaker (MCB), single-pole (1 P), rated at 16 A with a B-characteristic trip curve. Designed for use in low-voltage distribution systems, this breaker provides reliable overload and short-circuit protection with a breaking capacity of 10 kA (EN 60898) and up to 20 kA per IEC 60947-2 standards.

Key Features

  • Single-pole miniature circuit breaker (MCB) in the SENTRON 5SY4 series
  • Rated current: 16 A
  • Tripping characteristic: B (fast trip for moderate overloads)
  • Rated breaking capacity: 10 kA at 230/400 V AC (EN 60898) and up to 20 kA per IEC standards
  • Compact width: 18 mm (1 module width unit) and 70 mm installation depth
  • Mounts on DIN rail (35 mm) within distribution cabinets
  • Auxiliary features: Touch protection (IP20 with connected conductors), halogen-free, sealable design

Technical Specifications

  • Article Number: 5SY4116-6
  • Series: SENTRON 5SY4 miniature circuit breaker
  • Number of Poles: 1 (single-pole)
  • Rated Current (In): 16 A
  • Supply Voltage: 230/400 V AC, 50/60 Hz
  • Rated Insulation Voltage (Ui): 440 V (AC)
  • Degree of Pollution: 3
  • Overvoltage Category: III
  • Rated Breaking Capacity (Icn): 10 kA (EN 60898), 20 kA (IEC 60947-2)
  • Width: 18 mm (≈1 module)
  • Installation Depth: 70 mm
  • Mechanical Service Life: approx. 10 000 switching operations
  • Operating Ambient Temperature: –40 °C … +70 °C

Compliance & Certifications

  • Conforms to EN 60898-1, IEC/EN 60947-2 standards for miniature circuit breakers
  • Manufactured under Siemens SENTRON industrial-protection equipment quality standards

Applications

Used in low-voltage distribution boards, consumer units, control panels and switchgear where single-pole protection is required for branch circuits, lighting or small loads. The B-curve characteristic makes it particularly suitable for circuits with purely resistive or low inrush loads.

Technical Specifications

Additional equipment possibleYes
Ambient temperature during operating70 °C
Built-in depth70 mm
Connectable conductor cross section multi-wired35 mm²
Connectable conductor cross section solid-core35 mm²
Current limiting class3
Degree of protection (IP)IP20
Frequency50 Hz
Number of poles (total)1
Number of protected poles1
Over voltage category3
Pollution degree3
Power loss1.8 W
Rated current16 A
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui440 V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20 kA
Rated voltage400 V
Release characteristicB
Voltage typeAC
Width in number of modular spacings1
View complete specifications on Siemens

Videos & Media

Product Overview

Overview, features and application examples