Siemens

Siemens Circuit breaker 3VA1, class S, 4-pole, 36kA @ 415V, 125A Part number 3VA1112-4ED46-0AA0

EAN / Barcode 4042948822784
Product Type Control Panel
Product Class Power circuit-breaker for trafo/generator/installation protection
ETIM Class Power circuit-breaker for trafo/generator/installation protection
Back Order
View Full Product Details on Siemens 💬 Ask an Expert - Technical Support Available

Product Description

Product Overview

The Siemens 3VA1125-4ED46-0AA0 is a molded-case circuit breaker (MCCB) from the SENTRON 3VA1 series, engineered for dependable line and feeder protection in industrial and commercial power distribution. With a 4-pole configuration and a rated current of 125 A, it delivers high short-circuit performance in a compact frame for panel-space efficiency.

Key Features

  • Four-pole MCCB for 3-phase + neutral systems
  • Rated current: 125 A
  • High breaking capacity (class S) for robust fault protection
  • Thermal-magnetic trip unit for reliable overload and short-circuit protection
  • Fixed-mounted design with box terminals for straightforward installation
  • Compact 3VA1 frame for space-saving switchboard layouts

Technical Specifications

  • Product Series: SENTRON 3VA1
  • Article Number: 3VA1125-4ED46-0AA0
  • Number of Poles: 4 (3 + N)
  • Rated Current (In): 125 A
  • Operational Voltage: up to 690 V AC (application-dependent)
  • Breaking Capacity: class S (application-dependent values)
  • Trip Unit: Thermal-magnetic
  • Mounting: Fixed, box terminals

Compliance & Certifications

  • Manufactured to Siemens SENTRON quality standards
  • Meets international MCCB standards for low-voltage switchgear
  • RoHS compliant

Applications

Suitable for feeders and sub-distribution in industrial plants, commercial buildings, and infrastructure projects—where compact size, 125 A rated current, and high short-circuit capability are required for reliable protection and selectivity.

Technical Specifications

Adjustment range undelayed short-circuit release1250 A
Complete device with protection unitYes
Degree of protection (IP)IP40
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Number of poles4
Overload release current setting125 A
Position of connection for main current circuitFront side
Power loss28.1 W
Rated permanent current Iu125 A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36 kA
Rated voltage690 V
Suitable for DIN rail (top hat rail) mountingYes
Type of control elementRocker lever
Type of electrical connection of main circuitFrame clamp
View complete specifications on Siemens

Videos & Media

Product Overview

Overview, features and application examples