Illuminated metallic complete unit with contact function. It combines simplicity of installation, flexibility, and robustness. It meets the requirements of the majority of industrial applications.\nEmergency switching off push-button / Emergency stop push-button has a red mushroom Ø 40 mm, unmarked operator profile, round shape of signalling unit head, trigger action and mechanical latching operator, Chromium plated metal bezel material and 22 mm mounting diameter, turn to release reset, slow-break contact operation to name a few.\n\nSwitch ON/OFF 10A electrical contact, and/or provide visual signalling for 20 years with 0.5W power consumption at 30% use rate.
\nIP Rating / Detailed | IP66 conforming to IEC 60529 |
Compliance/Certifications | IEC 60204-1,IEC 60947-1,UL 508,IEC 60364-5-53,ISO 13850,CSA C22.2 No 14,IEC 60947-5-1,IEC 60947-5-4,JIS C8201-5-1,IEC 60947-5-5,JIS C8201-1 |
Temperature: Operating | -40…70 °C |
Part Depth (mm) | 82mm |
Part Width (mm) | 40mm |
Part Height (mm) | 47mm |
Material: Product | Silver alloy (Ag/Ni) |
Screw Type | Cross compatible with Philips no 1 screwdriver,Cross compatible with pozidriv No 1 screwdriver,Slotted compatible with flat Ø 4 mm screwdriver,Slotted compatible with flat Ø 5.5 mm screwdriver |
Connection Style | 1 NO + 1 NC |
Connection Type | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1,Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
Current Rating | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1,6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1,0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1,0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1,0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1,1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
Operating Period(Mech) | 300000 cycles |
Operating Period(Elec) | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |