Illuminated metallic complete unit with contact function. It combines simplicity of installation, flexibility, and robustness. It meets the requirements of the majority of industrial applications. Illuminated double-headed push-button, green standard handle, rectangular shape of signalling unit head, standard head type, Chromium plated metal bezel material, 22 mm mounting diameter, slow-break contact operation, spring return operator, 1 flush- 1 projecting push-buttons – 1 central pilot light, green” I”- red” O”, 1 NO + 1 NC contact type and composition, white marking when green, red or black caps and black making when white caps, protected LED light source and a white light source colour to name a few. Switch ON/OFF 10A electrical contact, and/or provide visual signalling for 20 years with 0.5W power consumption at 30% use rate.
IP Rating / Detailed | IP66 conforming to IEC 60529 |
Compliance/Certifications | IEC 60947-1,IEC 60947-5-1,CSA C22.2 No 14,JIS C8201-5-1,IEC 60947-5-5,IEC 60947-5-4,UL 508,JIS C8201-1 |
Temperature: Operating | -40…70 °C |
Material: Product | Silver alloy (Ag/Ni) |
Screw Type | Cross compatible with JIS No 1 screwdriver,Cross compatible with Philips no 1 screwdriver,Cross compatible with pozidriv No 1 screwdriver,Slotted compatible with flat Ø 4 mm screwdriver,Slotted compatible with flat Ø 5.5 mm screwdriver |
Connection Style | 1 NO + 1 NC |
Connection Type | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1,Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
Supply Voltage | 24 V AC/DC at 50/60 Hz |
Current Rating | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1,6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1,0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1,0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1,0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1,1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
Current Consumption | 18 mA |
Operating Period(Mech) | 1000000 cycles |
Operating Period(Elec) | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C,1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Colour | of marking |