\nThe type NZ.VZ safety switch has a standardized basic housing according to EN 50 041. The extremely sturdy, die-cast alloy housing in conjunction with the high degree of protection IP67 permits use under extreme ambient conditions. The Actuating head that can be turned in 90° stages,\nSwitching elements with 2 or 4 switching contacts and available with LED indicator. The Plug connector SVM5
\n538H | Slow-action switching contact 2 positively driven, positively driven contact |
1 | Right-angle plug connector: cable outlet adjustable max. 270° Default setting for cable outlet to the right. |
2 | Plug connector aligned |
3 | Actuating direction can be changed |
4 | Standard |
5 | Do not use actuator as an end stop. Limit overtravel separately. |
a | Travel without operation: actuator is in the guide slot, but function is not triggered. |
b | Switching operation completed: actuator must be inserted to this point to ensure safe switching. The actuator must be withdrawn at least to point a for switching off. |
Connection cross section | 0.34 - 1.5 mm² |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Utilization category | |
DC-13 | 4 A 24 V (>70 °C =>2 A) |
AC-15 | 4 A 30 V (>70 °C =>2 A) |
Short circuit protection according to IEC 60269-1 | 4A gG (> 70 °C => 2A gG) |
Switching voltage | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A (>70 °C =>2 A) |
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | 1 x Plug connector SVM5 (4-pin + PE) |
Number of door position positively driven contacts | 2 |
Extraction force | 35 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 52 mm |
Mechanical life | 2 x 10⁶ |
Retention force | 8 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -25 to 80 °C |
Material | |
Housing | Anodized die-cast alloy |
Contact | Silver alloy, gold flashed |
B10D | Mission time | |
Monitoring of the guard position | 4.5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V
Overtravel | |
4 mm |
Overtravel | |
16 mm |