{"title":"Siemens SIRIUS","description":null,"products":[{"product_id":"siemens-auxiliary-switch-transverse-screw-1-no-1-nc","title":"Siemens Auxiliary switch transverse, screw, 1 NO+1 NC","description":"\u003cp\u003eThe SIRIUS 3RV2901-1E is a transverse auxiliary switch designed for front-mounted integration with 3RV2 circuit breakers. This compact auxiliary contact block provides 1 NO + 1 NC contact configuration with screw terminal connections, offering versatile circuit breaker status monitoring and control capabilities in industrial automation applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis auxiliary switch is part of the SIRIUS modular system, featuring a unique transverse (front-mounted) design that differs from side-mounted versions. Provides simple, efficient, and reliable signaling with mechanical fixed actuator and copper contacts, suitable for applications requiring both normally open and normally closed contact configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 1 NO + 1 NC (1 Normally Open + 1 Normally Closed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Transverse (front-mounted)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size Compatibility:\u003c\/strong\u003e S00\/S0\/S3 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Products:\u003c\/strong\u003e 3RV2 series circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 0.5A at AC-15, 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator Type:\u003c\/strong\u003e Mechanical fixed actuator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Material:\u003c\/strong\u003e Copper contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.018kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 2 (1 NO + 1 NC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Changeover Contacts:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Positions:\u003c\/strong\u003e 2-position operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Current:\u003c\/strong\u003e 0.5A at AC-15, 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 1 NO + 1 NC arrangement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Suitable for low-current control circuit applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Life:\u003c\/strong\u003e High-reliability contact operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life:\u003c\/strong\u003e Extended operational cycles for control applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e Suitable for industrial voltage levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign \u0026amp; Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures unique transverse (front-mounted) design with clip-on mounting mechanism for easy installation. The mechanical fixed actuator provides reliable contact operation linked directly to circuit breaker position. Screw terminal connections ensure secure electrical connections for both NO and NC circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis transverse auxiliary switch is designed for various control and monitoring applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCircuit breaker status monitoring with dual contact states\u003c\/li\u003e\n\u003cli\u003eControl circuit interlocking requiring both NO and NC contacts\u003c\/li\u003e\n\u003cli\u003eAlarm and signaling systems with complementary outputs\u003c\/li\u003e\n\u003cli\u003eMotor control applications requiring status feedback\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems with mixed signal requirements\u003c\/li\u003e\n\u003cli\u003eProcess control applications with dual-state indication\u003c\/li\u003e\n\u003cli\u003eSafety circuit applications requiring fail-safe operation\u003c\/li\u003e\n\u003cli\u003eRemote indication with both active and passive signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Transverse (front-mounted) on 3RV2 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Clip-on design for easy attachment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Method:\u003c\/strong\u003e Front-mounting with secure clip mechanism\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Compatible with 3RV2 series circuit breakers S00-S3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool Requirements:\u003c\/strong\u003e Standard screwdriver for terminal connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessibility:\u003c\/strong\u003e Front-accessible for easy maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSIRIUS System Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular System:\u003c\/strong\u003e Part of the comprehensive SIRIUS modular system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for 3RV2 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Can be combined with other SIRIUS components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardization:\u003c\/strong\u003e Consistent design and connections across SIRIUS range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Generation:\u003c\/strong\u003e Part of modern SIRIUS product line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring \u0026amp; Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Range:\u003c\/strong\u003e Standard control circuit wire sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Screw-clamp connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Markings:\u003c\/strong\u003e Clearly marked NO and NC terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessibility:\u003c\/strong\u003e Easy access for wiring and maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Circuits:\u003c\/strong\u003e Independent NO and NC terminal sets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Configuration Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNO Contact:\u003c\/strong\u003e Closes when circuit breaker is ON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNC Contact:\u003c\/strong\u003e Opens when circuit breaker is ON\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Operation:\u003c\/strong\u003e Direct mechanical linkage to circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplementary Action:\u003c\/strong\u003e NO and NC contacts operate in opposite states\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Electrical isolation between contact circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliability:\u003c\/strong\u003e Positive mechanical operation ensures reliable switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTransverse Design Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Efficiency:\u003c\/strong\u003e Front-mounting saves lateral space\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Access:\u003c\/strong\u003e Front-accessible for maintenance and wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Installation:\u003c\/strong\u003e Minimal additional footprint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Indication:\u003c\/strong\u003e Easy to identify switch position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Reliability:\u003c\/strong\u003e Direct mechanical actuation from circuit breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Czech Republic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209790964\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Compliant with current substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A: Standard stock item\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Standards:\u003c\/strong\u003e Manufactured to Siemens quality standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Operation:\u003c\/strong\u003e Mechanical operation linked to circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition Indication:\u003c\/strong\u003e Direct indication of circuit breaker status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Instantaneous operation with circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Industrial temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Suitable for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Robust construction for industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e 3RV1901-1E (previous generation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent Products:\u003c\/strong\u003e Comparable to Schneider Electric Square D GVAE11 \u0026amp; LA1LC021\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for 3RV2 series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize Range:\u003c\/strong\u003e Compatible with S00\/S0\/S3 frame sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Transverse design provides alternative to side-mounted versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device is designed for industrial environments and meets environmental compliance requirements. It complies with WEEE take-back obligations and RoHS substance restrictions for environmentally responsible manufacturing and disposal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Contact States:\u003c\/strong\u003e Provides both NO and NC contacts for versatile applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Reliability:\u003c\/strong\u003e Direct mechanical operation ensures positive contact action\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Transverse mounting minimizes space requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Clip-on design simplifies installation process\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Access:\u003c\/strong\u003e Front-mounted design provides easy access for service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RV2901-1E\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RV2901-1E\/auxiliary-switch-transverse-1no-1nc?pid=427164\u0026amp;dtp=\u0026amp;mlfb=3RV2901-1E\u0026amp;lc=en-ww\"\u003eCAD Models and Technical Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2901-1E\"\u003eProduct Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/auxiliary-switch-installation-3RV2901-1E?lc=en-ww\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067723840,"sku":"3RV2901-1E","price":194.4,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/d44dff9420e55544b12ffbab1a2b7517.png?v=1743420044"},{"product_id":"siemens-auxiliary-switch-screw-1-no-1-nc","title":"Siemens Auxiliary switch, screw, 1 NO+1 NC","description":"\u003cp\u003eThe SIRIUS 3RV2901-1A is a side-mounted auxiliary switch designed for seamless integration with 3RV2 circuit breakers. This compact auxiliary contact block provides 1 NO + 1 NC contact configuration with screw terminal connections, enabling remote monitoring and control of circuit breaker status in industrial automation applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis auxiliary switch is part of the SIRIUS modular system, providing simple, efficient, and reliable signaling for circuit breaker applications. Features side-mounting design for easy installation and maintenance, with robust construction suitable for industrial environments and applications requiring circuit breaker status feedback.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 1 NO + 1 NC (1 Normally Open + 1 Normally Closed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Side-mounted (lateral)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size Compatibility:\u003c\/strong\u003e S00\/S0 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Products:\u003c\/strong\u003e 3RV2 series circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Current:\u003c\/strong\u003e 4A at AC-15, 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 690V AC \/ 250V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 2A \/ 10A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.044kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 90 x 9.5 x 70mm (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e 2 (1 NO + 1 NC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Changeover Contacts:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Voltage Rating:\u003c\/strong\u003e Up to 690V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating:\u003c\/strong\u003e Up to 250V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Current:\u003c\/strong\u003e 4A at AC-15, 230V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Material:\u003c\/strong\u003e Copper contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Suitable for control circuit applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Life:\u003c\/strong\u003e High-reliability contact operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Life:\u003c\/strong\u003e Extended operational cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign \u0026amp; Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures compact side-mounting design with screw terminal connections for secure and reliable electrical connections. The auxiliary switch is designed for plug-in fixing, making installation and maintenance straightforward. Robust construction ensures reliable operation in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis auxiliary switch is designed for various control and monitoring applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCircuit breaker status monitoring\u003c\/li\u003e\n\u003cli\u003eRemote indication of circuit breaker position\u003c\/li\u003e\n\u003cli\u003eControl circuit interlocking\u003c\/li\u003e\n\u003cli\u003eAlarm and signaling systems\u003c\/li\u003e\n\u003cli\u003eMotor control applications\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli\u003eProcess control applications\u003c\/li\u003e\n\u003cli\u003eSafety circuit applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Side-mounted on 3RV2 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Plug-in fixing for easy attachment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Quantity:\u003c\/strong\u003e Up to 4 auxiliary contacts per circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombination:\u003c\/strong\u003e Can be combined with other auxiliary switches and signaling switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Compatible with all 3RV2 series circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool Requirements:\u003c\/strong\u003e Standard screwdriver for terminal connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSIRIUS System Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular System:\u003c\/strong\u003e Part of the comprehensive SIRIUS modular system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for 3RV2 circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Can be combined with other SIRIUS components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardization:\u003c\/strong\u003e Consistent design and connections across SIRIUS range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-Proof:\u003c\/strong\u003e Part of current generation SIRIUS products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring \u0026amp; Connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Range:\u003c\/strong\u003e Standard control circuit wire sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Screw-clamp connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Markings:\u003c\/strong\u003e Clearly marked NO and NC terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessibility:\u003c\/strong\u003e Easy access for wiring and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Romania\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209737075\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Compliant with current substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A: Standard stock item\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Standards:\u003c\/strong\u003e Manufactured to Siemens quality standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Operation:\u003c\/strong\u003e Mechanical operation linked to circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition Indication:\u003c\/strong\u003e Direct indication of circuit breaker status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Instantaneous operation with circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Industrial temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Suitable for industrial environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e Robust construction for industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e 3RV1901-1A (previous generation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquivalent Products:\u003c\/strong\u003e Comparable to Schneider Electric Square D GVAN11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for 3RV2 series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Cannot be used with 3RV27 and 3RV28 circuit breakers (signaling switch applications)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device is designed for industrial environments and meets environmental compliance requirements. It complies with WEEE take-back obligations and RoHS substance restrictions for environmentally responsible manufacturing and disposal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLimitations \u0026amp; Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Quantity:\u003c\/strong\u003e A maximum of 4 auxiliary contacts with auxiliary switches can be attached per circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Auxiliary switches (2 contacts) and signaling switches can be attached individually or together\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestriction:\u003c\/strong\u003e The signaling switch cannot be used with the 3RV27 and 3RV28 circuit breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RV2901-1A\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RV2901-1A\/auxiliary-switch-side-mount-1no-1nc?pid=427164\u0026amp;dtp=\u0026amp;mlfb=3RV2901-1A\u0026amp;lc=en-ww\"\u003eCAD Models and Technical Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2901-1A\"\u003eProduct Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/auxiliary-switch-installation-3RV2901-1A?lc=en-ww\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067691072,"sku":"3RV2901-1A","price":194.4,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/efbc208494f69452eaca21ae3cb22a37.png?v=1743420047"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s0-18-25-a","title":"Siemens Circuit breaker for motor protection, size S0, 18...25 A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit breaker size S0 for motor protection, CLASS 10 A-release 18...25 A N-release 325 A screw terminal Standard switching capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 (45 mm width)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 18...25 A adjustable thermal overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit Release:\u003c\/strong\u003e 325 A (N-release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Class:\u003c\/strong\u003e CLASS 10 according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-1, EN 60947-1 (VDE 0660 Part 100)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2, EN 60947-2 (VDE 0660 Part 101)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102)\u003c\/li\u003e\n\u003cli\u003eUL 508 (UL 60947-4-1), CSA C22.2 No. 14 (CSA-C22.2 No. 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Temperature: -20°C to +70°C (with current reduction above +60°C)\u003c\/li\u003e\n\u003cli\u003eMounting Position: Any position according to IEC 60447\u003c\/li\u003e\n\u003cli\u003eDegree of Protection: IP20\u003c\/li\u003e\n\u003cli\u003eTouch Protection: Finger-safe according to DIN EN 50274\u003c\/li\u003e\n\u003cli\u003eNet Weight: Approximately 0.360 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase loss sensitivity for reliable motor protection\u003c\/li\u003e\n\u003cli\u003eIntegrated overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation from -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eTest function for operational verification\u003c\/li\u003e\n\u003cli\u003eIsolating function according to IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eExplosion protection approval for motors with \"increased safety\" type (EEx e)\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity up to 55 kA at 400V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor protection for three-phase motors (20-30 HP range)\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection for high-power applications\u003c\/li\u003e\n\u003cli\u003eSystem protection applications\u003c\/li\u003e\n\u003cli\u003eLoad feeder protection\u003c\/li\u003e\n\u003cli\u003eControl circuit switching\u003c\/li\u003e\n\u003cli\u003eSuitable for motors with rated currents between 18-25 A\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eManufacturing and production line equipment\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial applications\u003c\/li\u003e\n\u003cli\u003eLarge conveyor systems and industrial machinery\u003c\/li\u003e\n\u003cli\u003eHigh-capacity pump, fan, and compressor applications\u003c\/li\u003e\n\u003cli\u003eMaterial handling equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eUL Type E Approval\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Protected Combination Motor Controller (Type E):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL approved as Self Protected Combination Motor Controllers\u003c\/li\u003e\n\u003cli\u003eProvides all required functions for motor branch in one device\u003c\/li\u003e\n\u003cli\u003eIncludes disconnect, short circuit protection, motor control and overload protection\u003c\/li\u003e\n\u003cli\u003eEliminates need for separate components\u003c\/li\u003e\n\u003cli\u003eSuitable for North American installations\u003c\/li\u003e\n\u003cli\u003eRequires Type E terminal adaptor for full compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Screw: M4, Pozidriv size 2\u003c\/li\u003e\n\u003cli\u003eOperating Tool: Ø 5 to 6 mm\u003c\/li\u003e\n\u003cli\u003eSpecified Tightening Torque: 2.0 to 2.5 Nm\u003c\/li\u003e\n\u003cli\u003eConductor Cross-sections (1-wire or 2-wire connection possible):\n\u003cul\u003e\n\u003cli\u003eSolid and stranded: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 10) mm²\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 6) mm², max. 1 x 10 mm²\u003c\/li\u003e\n\u003cli\u003eAWG cables: 2 x (16 to 12), 2 x (14 to 8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories Available\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary switches (transverse and lateral)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt)\u003c\/li\u003e\n\u003cli\u003eDisconnector modules\u003c\/li\u003e\n\u003cli\u003eDoor-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eEnclosures and mounting accessories\u003c\/li\u003e\n\u003cli\u003eLink modules for contactor integration\u003c\/li\u003e\n\u003cli\u003e3-phase busbar systems\u003c\/li\u003e\n\u003cli\u003eSealable covers for tamper protection\u003c\/li\u003e\n\u003cli\u003ePhase barriers for enhanced safety\u003c\/li\u003e\n\u003cli\u003eType E terminal adaptors for UL compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: 35 mm DIN rail according to DIN EN 60715 or screw mounting\u003c\/li\u003e\n\u003cli\u003eClearance Requirements: 30 mm from grounded or live parts\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminals for secure and reliable wiring\u003c\/li\u003e\n\u003cli\u003eModular System: Compatible with SIRIUS 3RT2 contactors and accessories\u003c\/li\u003e\n\u003cli\u003eSnap-on mounting for easy installation and removal\u003c\/li\u003e\n\u003cli\u003eSide-by-side mounting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Take-back obligation applies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Regularly screened for Substances of Very High Concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/CSA Approvals:\u003c\/strong\u003e Available for North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Approval:\u003c\/strong\u003e For hazardous area applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A - Standard product, stock item with return guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eQuality \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in Germany with strict quality control\u003c\/li\u003e\n\u003cli\u003eLong-term stability with proven bimetal technology\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eMaximum switching frequency: 15 starts per hour\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting characteristics for enhanced protection\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance according to IEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eMotor Protection Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents motor damage from overload conditions\u003c\/li\u003e\n\u003cli\u003eProtects against phase loss and unbalanced loads\u003c\/li\u003e\n\u003cli\u003eReduces downtime with reliable trip characteristics\u003c\/li\u003e\n\u003cli\u003eExtends motor life through precise current monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for standard and energy-efficient IE3 motors\u003c\/li\u003e\n\u003cli\u003eOptimized for side-by-side installation in control panels\u003c\/li\u003e\n\u003cli\u003eSuperior N-release rating (325A) for high-power applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDesign Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobust screw terminal design for industrial environments\u003c\/li\u003e\n\u003cli\u003eClear current setting scale for easy adjustment (18-25A range)\u003c\/li\u003e\n\u003cli\u003eIntegrated test function for maintenance verification\u003c\/li\u003e\n\u003cli\u003eCompact 45mm width for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eLockable rotary operating mechanism\u003c\/li\u003e\n\u003cli\u003eVisual trip indication for quick fault identification\u003c\/li\u003e\n\u003cli\u003eEnhanced short-circuit protection with 325A N-release\u003c\/li\u003e\n\u003cli\u003eRotary ON\/OFF handle for manual operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eHigh-Power Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for larger industrial motors and equipment\u003c\/li\u003e\n\u003cli\u003eEnhanced short-circuit protection with 325A N-release\u003c\/li\u003e\n\u003cli\u003eIdeal for applications requiring higher current ratings (18-25A)\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous operation in demanding environments\u003c\/li\u003e\n\u003cli\u003eOptimized for IE3 energy-efficient motors\u003c\/li\u003e\n\u003cli\u003eEnhanced protection for high-value industrial equipment\u003c\/li\u003e\n\u003cli\u003ePerfect for heavy-duty applications requiring robust protection\u003c\/li\u003e\n\u003cli\u003eSuitable for motors up to 30 HP at 480V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdvanced Protection Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Current Range:\u003c\/strong\u003e 18-25A suitable for large motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Short-Circuit Protection:\u003c\/strong\u003e 325A N-release for maximum safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for IE3 Motors:\u003c\/strong\u003e Specially adapted for energy-efficient motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Trip Characteristics:\u003c\/strong\u003e CLASS 10 tripping for consistent performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensated:\u003c\/strong\u003e Stable operation across wide temperature ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Detection:\u003c\/strong\u003e Protects against unbalanced load conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Trip Elements:\u003c\/strong\u003e Fast response to short-circuit conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBimetallic Overload Protection:\u003c\/strong\u003e Accurate thermal protection for motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003eWiring Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003eCAD Data\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003e3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/172\/60279172\/att_71569\/v1\/manual_SIRIUS_Innovations_circuit_breaker_3RV2_en-US.pdf\"\u003eProduct Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/configurators\"\u003eConfiguration Tool\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4DA10\"\u003eProduct Support Portal\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/manuals\"\u003eSIRIUS System Overview\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/technical-assistance\"\u003eTechnical Assistance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/training\"\u003eOnline Training\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/mall\"\u003eIndustry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067494464,"sku":"3RV2021-4DA10","price":1944.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/c71f26d9983d288d2a89bcc1a0a7f126.png?v=1743420060"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s0-260a","title":"Siemens Circuit breaker for motor protection, size S0, 260A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit breaker size S0 for motor protection, CLASS 10 A-release 13...20 A N-release 260 A screw terminal Standard switching capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 (45 mm width)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 13...20 A adjustable thermal overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit Release:\u003c\/strong\u003e 260 A (N-release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Class:\u003c\/strong\u003e CLASS 10 according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-1, EN 60947-1 (VDE 0660 Part 100)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2, EN 60947-2 (VDE 0660 Part 101)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102)\u003c\/li\u003e\n\u003cli\u003eUL 508 (UL 60947-4-1), CSA C22.2 No. 14 (CSA-C22.2 No. 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Temperature: -20°C to +70°C (with current reduction above +60°C)\u003c\/li\u003e\n\u003cli\u003eMounting Position: Any position according to IEC 60447\u003c\/li\u003e\n\u003cli\u003eDegree of Protection: IP20\u003c\/li\u003e\n\u003cli\u003eTouch Protection: Finger-safe according to DIN EN 50274\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.360 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase loss sensitivity for reliable motor protection\u003c\/li\u003e\n\u003cli\u003eIntegrated overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation from -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eTest function for operational verification\u003c\/li\u003e\n\u003cli\u003eIsolating function according to IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eExplosion protection approval for motors with \"increased safety\" type (EEx e)\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity up to 55 kA at 400V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor protection for three-phase motors (15-25 HP range)\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection for high-power applications\u003c\/li\u003e\n\u003cli\u003eSystem protection applications\u003c\/li\u003e\n\u003cli\u003eLoad feeder protection\u003c\/li\u003e\n\u003cli\u003eControl circuit switching\u003c\/li\u003e\n\u003cli\u003eSuitable for motors with rated currents between 13-20 A\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eManufacturing and production line equipment\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial applications\u003c\/li\u003e\n\u003cli\u003eLarge conveyor systems and industrial machinery\u003c\/li\u003e\n\u003cli\u003eHigh-capacity pump and fan applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Screw: M4, Pozidriv size 2\u003c\/li\u003e\n\u003cli\u003eOperating Tool: Ø 5 to 6 mm\u003c\/li\u003e\n\u003cli\u003eSpecified Tightening Torque: 2.0 to 2.5 Nm\u003c\/li\u003e\n\u003cli\u003eConductor Cross-sections (1-wire or 2-wire connection possible):\n\u003cul\u003e\n\u003cli\u003eSolid and stranded: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 10) mm²\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 6) mm², max. 1 x 10 mm²\u003c\/li\u003e\n\u003cli\u003eAWG cables: 2 x (16 to 12), 2 x (14 to 8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories Available\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary switches (transverse and lateral)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt)\u003c\/li\u003e\n\u003cli\u003eDisconnector modules\u003c\/li\u003e\n\u003cli\u003eDoor-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eEnclosures and mounting accessories\u003c\/li\u003e\n\u003cli\u003eLink modules for contactor integration\u003c\/li\u003e\n\u003cli\u003e3-phase busbar systems\u003c\/li\u003e\n\u003cli\u003eSealable covers for tamper protection\u003c\/li\u003e\n\u003cli\u003ePhase barriers for enhanced safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: 35 mm DIN rail according to DIN EN 60715 or screw mounting\u003c\/li\u003e\n\u003cli\u003eClearance Requirements: 30 mm from grounded or live parts\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminals for secure and reliable wiring\u003c\/li\u003e\n\u003cli\u003eModular System: Compatible with SIRIUS 3RT2 contactors and accessories\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions: 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003eSnap-on mounting for easy installation and removal\u003c\/li\u003e\n\u003cli\u003eSide-by-side mounting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Take-back obligation applies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Regularly screened for Substances of Very High Concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/CSA Approvals:\u003c\/strong\u003e Available for North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Approval:\u003c\/strong\u003e For hazardous area applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A - Standard product, stock item with return guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eQuality \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in Germany with strict quality control\u003c\/li\u003e\n\u003cli\u003eLong-term stability with proven bimetal technology\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eMaximum switching frequency: 15 starts per hour\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting characteristics for enhanced protection\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance according to IEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eMotor Protection Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents motor damage from overload conditions\u003c\/li\u003e\n\u003cli\u003eProtects against phase loss and unbalanced loads\u003c\/li\u003e\n\u003cli\u003eReduces downtime with reliable trip characteristics\u003c\/li\u003e\n\u003cli\u003eExtends motor life through precise current monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for standard and energy-efficient IE3 motors\u003c\/li\u003e\n\u003cli\u003eOptimized for side-by-side installation in control panels\u003c\/li\u003e\n\u003cli\u003eEnhanced N-release rating (260A) for high-power applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDesign Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobust screw terminal design for industrial environments\u003c\/li\u003e\n\u003cli\u003eClear current setting scale for easy adjustment (13-20A range)\u003c\/li\u003e\n\u003cli\u003eIntegrated test function for maintenance verification\u003c\/li\u003e\n\u003cli\u003eCompact 45mm width for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eLockable rotary operating mechanism\u003c\/li\u003e\n\u003cli\u003eVisual trip indication for quick fault identification\u003c\/li\u003e\n\u003cli\u003eSuperior short-circuit protection with 260A N-release\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eHigh-Power Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for larger industrial motors and equipment\u003c\/li\u003e\n\u003cli\u003eEnhanced short-circuit protection with 260A N-release\u003c\/li\u003e\n\u003cli\u003eIdeal for applications requiring higher current ratings (13-20A)\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous operation in demanding environments\u003c\/li\u003e\n\u003cli\u003eOptimized for IE3 energy-efficient motors\u003c\/li\u003e\n\u003cli\u003eEnhanced protection for high-value industrial equipment\u003c\/li\u003e\n\u003cli\u003ePerfect for heavy-duty applications requiring robust protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdvanced Protection Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Current Range:\u003c\/strong\u003e 13-20A suitable for medium to large motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Short-Circuit Protection:\u003c\/strong\u003e 260A N-release for enhanced safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for IE3 Motors:\u003c\/strong\u003e Specially adapted for energy-efficient motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Trip Characteristics:\u003c\/strong\u003e CLASS 10 tripping for consistent performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensated:\u003c\/strong\u003e Stable operation across wide temperature ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Detection:\u003c\/strong\u003e Protects against unbalanced load conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003eWiring Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003eCAD Data\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003e3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/172\/60279172\/att_71569\/v1\/manual_SIRIUS_Innovations_circuit_breaker_3RV2_en-US.pdf\"\u003eProduct Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/configurators\"\u003eConfiguration Tool\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4BA10\"\u003eProduct Support Portal\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/manuals\"\u003eSIRIUS System Overview\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/technical-assistance\"\u003eTechnical Assistance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/training\"\u003eOnline Training\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/mall\"\u003eIndustry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067428928,"sku":"3RV2021-4BA10","price":1611.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/db89a696ba52e5117ba6b2833d93c190.png?v=1743420063"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-104a","title":"Siemens Circuit breaker for motor protection, size S00, 104A","description":"\u003cp\u003eCircuit breaker size S00 for motor protection, CLASS 10 A-release 5.5...8 A N-release 104 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3\/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL\/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067396160,"sku":"3RV2011-1HA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/9772a969597c2e32960930170eaf6a2d.png?v=1743420063"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s0-400a","title":"Siemens Circuit breaker for motor protection, size S0, 400A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit breaker size S0 for motor protection, CLASS 10 A-release 27...32 A N-release 400 A screw terminal Standard switching capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 (45 mm width)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 27...32 A adjustable thermal overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit Release:\u003c\/strong\u003e 400 A (N-release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Class:\u003c\/strong\u003e CLASS 10 according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-1, EN 60947-1 (VDE 0660 Part 100)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2, EN 60947-2 (VDE 0660 Part 101)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102)\u003c\/li\u003e\n\u003cli\u003eUL 508 (UL 60947-4-1), CSA C22.2 No. 14 (CSA-C22.2 No. 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Temperature: -20°C to +70°C (with current reduction above +60°C)\u003c\/li\u003e\n\u003cli\u003eMounting Position: Any position according to IEC 60447\u003c\/li\u003e\n\u003cli\u003eDegree of Protection: IP20\u003c\/li\u003e\n\u003cli\u003eTouch Protection: Finger-safe according to DIN EN 50274\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.379 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase loss sensitivity for reliable motor protection\u003c\/li\u003e\n\u003cli\u003eIntegrated overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation from -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eTest function for operational verification\u003c\/li\u003e\n\u003cli\u003eIsolating function according to IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eExplosion protection approval for motors with \"increased safety\" type (EEx e)\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity up to 55 kA at 400V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor protection for three-phase motors (30-40 HP range)\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection for high-power applications\u003c\/li\u003e\n\u003cli\u003eSystem protection applications\u003c\/li\u003e\n\u003cli\u003eLoad feeder protection\u003c\/li\u003e\n\u003cli\u003eControl circuit switching\u003c\/li\u003e\n\u003cli\u003eSuitable for motors with rated currents between 27-32 A\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eManufacturing and production line equipment\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial applications\u003c\/li\u003e\n\u003cli\u003eLarge conveyor systems and industrial machinery\u003c\/li\u003e\n\u003cli\u003eHigh-capacity pump, fan, and compressor applications\u003c\/li\u003e\n\u003cli\u003eMaterial handling and processing equipment\u003c\/li\u003e\n\u003cli\u003eLarge industrial mixers and agitators\u003c\/li\u003e\n\u003cli\u003eHigh-power HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection Screw: M4, Pozidriv size 2\u003c\/li\u003e\n\u003cli\u003eOperating Tool: Ø 5 to 6 mm\u003c\/li\u003e\n\u003cli\u003eSpecified Tightening Torque: 2.0 to 2.5 Nm\u003c\/li\u003e\n\u003cli\u003eConductor Cross-sections (1-wire or 2-wire connection possible):\n\u003cul\u003e\n\u003cli\u003eSolid and stranded: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 10) mm²\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 6) mm², max. 1 x 10 mm²\u003c\/li\u003e\n\u003cli\u003eAWG cables: 2 x (16 to 12), 2 x (14 to 8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories Available\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary switches (transverse and lateral)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt)\u003c\/li\u003e\n\u003cli\u003eDisconnector modules\u003c\/li\u003e\n\u003cli\u003eDoor-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eEnclosures and mounting accessories\u003c\/li\u003e\n\u003cli\u003eLink modules for contactor integration\u003c\/li\u003e\n\u003cli\u003e3-phase busbar systems\u003c\/li\u003e\n\u003cli\u003eSealable covers for tamper protection\u003c\/li\u003e\n\u003cli\u003ePhase barriers for enhanced safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: 35 mm DIN rail according to DIN EN 60715 or screw mounting\u003c\/li\u003e\n\u003cli\u003eClearance Requirements: 30 mm from grounded or live parts\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminals for secure and reliable wiring\u003c\/li\u003e\n\u003cli\u003eModular System: Compatible with SIRIUS 3RT2 contactors and accessories\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions: 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003eSnap-on mounting for easy installation and removal\u003c\/li\u003e\n\u003cli\u003eSide-by-side mounting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Take-back obligation applies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Contains lead and lead titanium zirconium oxide in concentrations \u0026gt;0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/CSA Approvals:\u003c\/strong\u003e Available for North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Approval:\u003c\/strong\u003e For hazardous area applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A - Standard product, stock item with return guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eQuality \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in Germany with strict quality control\u003c\/li\u003e\n\u003cli\u003eLong-term stability with proven bimetal technology\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eMaximum switching frequency: 15 starts per hour\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting characteristics for enhanced protection\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance according to IEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eMotor Protection Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents motor damage from overload conditions\u003c\/li\u003e\n\u003cli\u003eProtects against phase loss and unbalanced loads\u003c\/li\u003e\n\u003cli\u003eReduces downtime with reliable trip characteristics\u003c\/li\u003e\n\u003cli\u003eExtends motor life through precise current monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for standard and energy-efficient IE3 motors\u003c\/li\u003e\n\u003cli\u003eOptimized for side-by-side installation in control panels\u003c\/li\u003e\n\u003cli\u003eMaximum N-release rating (400A) for highest power applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDesign Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobust screw terminal design for industrial environments\u003c\/li\u003e\n\u003cli\u003eClear current setting scale for easy adjustment (27-32A range)\u003c\/li\u003e\n\u003cli\u003eIntegrated test function for maintenance verification\u003c\/li\u003e\n\u003cli\u003eCompact 45mm width for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eLockable rotary operating mechanism\u003c\/li\u003e\n\u003cli\u003eVisual trip indication for quick fault identification\u003c\/li\u003e\n\u003cli\u003eMaximum short-circuit protection with 400A N-release\u003c\/li\u003e\n\u003cli\u003eRotary ON\/OFF handle for manual operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eMaximum Power Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest Current Rating:\u003c\/strong\u003e 27-32A for maximum motor sizes in S0 range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Short-Circuit Protection:\u003c\/strong\u003e 400A N-release for ultimate safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for Large Motors:\u003c\/strong\u003e Suitable for motors up to 40 HP at 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Applications:\u003c\/strong\u003e Designed for continuous operation in demanding environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for IE3 Motors:\u003c\/strong\u003e Specially adapted for energy-efficient motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Protection:\u003c\/strong\u003e Enhanced protection for high-value industrial equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Performance:\u003c\/strong\u003e Perfect for the most demanding motor protection applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdvanced Protection Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current Range:\u003c\/strong\u003e 27-32A for largest motors in size S0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltimate Short-Circuit Protection:\u003c\/strong\u003e 400A N-release for maximum safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized for IE3 Motors:\u003c\/strong\u003e Specially adapted for energy-efficient motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Trip Characteristics:\u003c\/strong\u003e CLASS 10 tripping for consistent performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Compensated:\u003c\/strong\u003e Stable operation across wide temperature ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Detection:\u003c\/strong\u003e Protects against unbalanced load conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Trip Elements:\u003c\/strong\u003e Fast response to short-circuit conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBimetallic Overload Protection:\u003c\/strong\u003e Accurate thermal protection for motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Design:\u003c\/strong\u003e Engineered for the most demanding applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Manufacturing Equipment:\u003c\/strong\u003e Protection for high-power production machinery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industries:\u003c\/strong\u003e Suitable for chemical, pharmaceutical, and food processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Conveyor systems, cranes, and hoists\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Large chillers, air handlers, and cooling towers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Treatment:\u003c\/strong\u003e High-capacity pumps and treatment equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMining and Quarrying:\u003c\/strong\u003e Heavy-duty equipment protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteel and Metal Processing:\u003c\/strong\u003e Rolling mills and processing equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Auxiliary equipment protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003ePerformance Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Motor Protection:\u003c\/strong\u003e Up to 40 HP at 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e 400A short-circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Operation:\u003c\/strong\u003e CLASS 10 trip characteristics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e -20°C to +70°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Durability:\u003c\/strong\u003e 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Control:\u003c\/strong\u003e Adjustable 27-32A range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e 45mm width for space efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Grade:\u003c\/strong\u003e German engineering and manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003eWiring Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003eCAD Data\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003e3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/172\/60279172\/att_71569\/v1\/manual_SIRIUS_Innovations_circuit_breaker_3RV2_en-US.pdf\"\u003eProduct Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/configurators\"\u003eConfiguration Tool\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4EA10\"\u003eProduct Support Portal\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/manuals\"\u003eSIRIUS System Overview\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/technical-assistance\"\u003eTechnical Assistance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/training\"\u003eOnline Training\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/mall\"\u003eIndustry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497458752,"sku":"3RV2021-4EA10","price":2475.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/f4dfba1bf431a91d6a78ae886c76efa6.png?v=1743420066"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-130a","title":"Siemens Circuit breaker for motor protection, size S00, 130A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e3RV2011-1JA10\u003c\/strong\u003e is a robust circuit breaker engineered for motor protection applications requiring higher current ratings. This size S00 device delivers reliable overload and short-circuit protection with a CLASS 10 A-release rating of 7...10 A and enhanced N-release of 130 A, featuring screw terminal connections and standard switching capacity for demanding industrial applications.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Circuit Protection:\u003c\/strong\u003e Provides comprehensive motor protection with integrated overload and short-circuit releases, designed for higher current applications while maintaining compact S00 form factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigher Current Rating:\u003c\/strong\u003e 7...10 A adjustable overload release with robust 130 A short-circuit release capacity, ideal for larger motors and high-performance applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Screw Terminals:\u003c\/strong\u003e Proven screw terminal technology ensures secure, long-lasting electrical connections with easy maintenance and inspection capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Size S00 form factor (45mm width) maximizes space efficiency while providing enhanced protection for motors up to 10A rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Grade Construction:\u003c\/strong\u003e Built for demanding industrial environments with superior reliability and consistent performance characteristics.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 7...10 A (adjustable)\u003c\/li\u003e\n\u003cli\u003eShort-circuit release: 130 A\u003c\/li\u003e\n\u003cli\u003eRated operational voltage: Up to 690V AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity: 100 kA at 400V AC\u003c\/li\u003e\n\u003cli\u003eRated frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eTripping class: CLASS 10 (IEC 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 45 x 97 x 91 mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.351 kg\u003c\/li\u003e\n\u003cli\u003eTerminal type: Screw terminals (M3)\u003c\/li\u003e\n\u003cli\u003eTightening torque: 0.8-1.2 Nm\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP20\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductor capacity: 2 x (0.75 to 2.5) mm² (solid and stranded)\u003c\/li\u003e\n\u003cli\u003eMaximum: 2 x 4 mm²\u003c\/li\u003e\n\u003cli\u003eAWG wire support: 2 x (18 to 14), 2 x 12\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (0.5 to 2.5) mm²\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -20°C to +60°C (with derating above 60°C)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -50°C to +80°C\u003c\/li\u003e\n\u003cli\u003eInstallation altitude: Up to 2000m\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eHumidity: 95% relative humidity (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1, IEC 60947-2\u003c\/strong\u003e - Low-voltage switchgear and controlgear standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1\u003c\/strong\u003e - Motor starter protector requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1 (UL 508)\u003c\/strong\u003e - North American safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14\u003c\/strong\u003e - Canadian safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e - Environmental compliance since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking\u003c\/strong\u003e - European conformity declaration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Directive\u003c\/strong\u003e - Take-back obligation compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHigher Current Motor Protection:\u003c\/strong\u003e Specifically designed for protecting three-phase motors with ratings from 7-10A, providing both overload and short-circuit protection in demanding industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Ideal for use in manufacturing equipment, conveyor systems, pumps, and other industrial machinery requiring reliable motor protection at higher current levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl Panel Integration:\u003c\/strong\u003e Perfect for integration into control panels and distribution boards where space is limited but higher current protection is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Protection:\u003c\/strong\u003e Suitable for protecting electrical systems and equipment in industrial environments with appropriate load balancing.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation and Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eScrew mounting on mounting plate with optional push-in lugs\u003c\/li\u003e\n\u003cli\u003eCompatible with standard industrial control cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum clearance from live parts: 30mm (lateral), 9mm (front\/back)\u003c\/li\u003e\n\u003cli\u003eSuitable for side-by-side mounting with appropriate spacing\u003c\/li\u003e\n\u003cli\u003eStand-alone or side-by-side design configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting position: Any orientation\u003c\/li\u003e\n\u003cli\u003eAmbient temperature derating required above 60°C\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor installation in enclosed spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories and Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLateral auxiliary switches (1 NO+1 NC, 2 NO, 2 NC contacts)\u003c\/li\u003e\n\u003cli\u003eTransverse auxiliary switches (1 CO, 1 NO+1 NC, 2 NO contacts)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for remote status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt releases)\u003c\/li\u003e\n\u003cli\u003eSealable cover for setting protection\u003c\/li\u003e\n\u003cli\u003eTerminal blocks and phase barriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with SIRIUS modular system components\u003c\/li\u003e\n\u003cli\u003eDirect mounting capability with contactors via link modules\u003c\/li\u003e\n\u003cli\u003eIntegration with 3-phase busbar systems (3RV1915 series)\u003c\/li\u003e\n\u003cli\u003eCompatible with door-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eSuitable for 3RV2917 infeed system integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSurface-mounting enclosures (IP55\/IP65)\u003c\/li\u003e\n\u003cli\u003eFlush-mounting enclosures (IP55 front, IP20 rear)\u003c\/li\u003e\n\u003cli\u003eFront plates for custom panel integration\u003c\/li\u003e\n\u003cli\u003eCast aluminum and molded plastic enclosure variants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/attachments\/60279172\/manual_SIRIUS_circuit_breaker_3RV_en-US.pdf\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAD and Engineering Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003e3D Models and CAD Files\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eDimensional Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eEPLAN Macros\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertificates and Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eProduct Certificates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eDeclaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eSafety Data Sheets\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/tst\"\u003eSelection Tools\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\"\u003eOnline Product Support\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eTechnical Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eConfiguration Guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067363392,"sku":"3RV2011-1JA10","price":1476.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/5e840858f80cd25779f68206b27789c1.png?v=1743420066"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-208a","title":"Siemens Circuit breaker for motor protection, size S00, 208A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e3RV2011-4AA10\u003c\/strong\u003e is a premium circuit breaker engineered for motor protection applications requiring the highest current ratings available in the S00 size category. This top-tier device delivers exceptional overload and short-circuit protection with a CLASS 10 A-release rating of 10...16 A and the maximum N-release of 208 A, featuring reliable screw terminal connections and standard switching capacity for the most demanding industrial applications.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current Capacity:\u003c\/strong\u003e Provides the highest current rating available in S00 size (10...16 A), designed for the largest motors that can be accommodated in the compact 45mm form factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Short-Circuit Protection:\u003c\/strong\u003e Features the highest N-release rating of 208 A in the S00 category, delivering unmatched short-circuit protection for the most demanding applications and high-performance motor systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePremium Screw Terminal Technology:\u003c\/strong\u003e Proven screw terminal connections ensure maximum reliability and secure electrical connections for critical high-current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact High-Capacity Design:\u003c\/strong\u003e Size S00 form factor (45mm width) delivers maximum protection capability while maintaining the smallest possible footprint for space-critical installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Premium Construction:\u003c\/strong\u003e Built for the most demanding industrial environments with superior reliability, robust construction, and consistent high-performance characteristics.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 10...16 A (adjustable)\u003c\/li\u003e\n\u003cli\u003eShort-circuit release: 208 A (N-release)\u003c\/li\u003e\n\u003cli\u003eRated operational voltage: Up to 690V AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity: 100 kA at 400V AC\u003c\/li\u003e\n\u003cli\u003eRated frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eTripping class: CLASS 10 (IEC 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 45 x 97 x 91 mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.359 kg\u003c\/li\u003e\n\u003cli\u003eTerminal type: Screw terminals (M3)\u003c\/li\u003e\n\u003cli\u003eTightening torque: 0.8-1.2 Nm\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP20\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductor capacity: 2 x (0.75 to 2.5) mm² (solid and stranded)\u003c\/li\u003e\n\u003cli\u003eMaximum: 2 x 4 mm²\u003c\/li\u003e\n\u003cli\u003eAWG wire support: 2 x (18 to 14), 2 x 12\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (0.5 to 2.5) mm²\u003c\/li\u003e\n\u003cli\u003eTool requirement: Pozidriv size PZ 2, Ø 5-6 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -20°C to +60°C (with derating above 60°C)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -50°C to +80°C\u003c\/li\u003e\n\u003cli\u003eInstallation altitude: Up to 2000m\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eHumidity: 95% relative humidity (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1, IEC 60947-2\u003c\/strong\u003e - Low-voltage switchgear and controlgear standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1\u003c\/strong\u003e - Motor starter protector requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1 (UL 508)\u003c\/strong\u003e - North American safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14\u003c\/strong\u003e - Canadian safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e - Environmental compliance since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking\u003c\/strong\u003e - European conformity declaration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Directive\u003c\/strong\u003e - Take-back obligation compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current Motor Protection:\u003c\/strong\u003e Specifically engineered for protecting three-phase motors with ratings from 10-16A, providing both overload and short-circuit protection for the largest motors accommodated in S00 size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Industrial Systems:\u003c\/strong\u003e Ideal for demanding industrial applications including heavy-duty machinery, large industrial pumps, high-capacity conveyor systems, and critical manufacturing equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Infrastructure Protection:\u003c\/strong\u003e Perfect for applications where maximum protection is essential in a compact form factor, such as critical infrastructure, automated production lines, and precision industrial processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePremium Motor Applications:\u003c\/strong\u003e Designed for high-performance motors with demanding startup characteristics, elevated inrush currents, and applications requiring the highest level of short-circuit protection available.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation and Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eScrew mounting on mounting plate with optional push-in lugs\u003c\/li\u003e\n\u003cli\u003eCompatible with standard industrial control cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Connection Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecure screw terminal connections essential for maximum current handling\u003c\/li\u003e\n\u003cli\u003eProper conductor sizing and termination critical for optimal performance\u003c\/li\u003e\n\u003cli\u003eRegular inspection recommended for high-current applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum clearance from live parts: 30mm (lateral), 9mm (front\/back)\u003c\/li\u003e\n\u003cli\u003eAdequate ventilation required for high-current operation\u003c\/li\u003e\n\u003cli\u003eStand-alone or side-by-side design configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003ePerformance Characteristics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Overload Protection:\u003c\/strong\u003e Adjustable current setting from 10-16A provides precise protection for high-current motors while maintaining CLASS 10 tripping characteristics for reliable operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Short-Circuit Protection:\u003c\/strong\u003e Enhanced 208A N-release provides the highest level of protection against short-circuit conditions available in S00 size, ensuring safe disconnection and equipment protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Temperature-compensated overload release with enhanced thermal characteristics ensures consistent protection across the full operating temperature range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Loss Sensitivity:\u003c\/strong\u003e Integrated phase loss detection prevents motor damage from unbalanced supply conditions and phase failures, critical for high-current applications.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eSelection Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum S00 Capability:\u003c\/strong\u003e Offers the highest current rating available in the compact S00 form factor, eliminating the need to move to larger sizes for currents up to 16A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpace Optimization:\u003c\/strong\u003e Delivers maximum protection capability while maintaining the smallest possible footprint, ideal for space-constrained installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCost-Effective Solution:\u003c\/strong\u003e Provides premium protection without requiring larger, more expensive devices for currents within the 10-16A range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuture-Proof Design:\u003c\/strong\u003e Accommodates motor upgrades and system expansions within the current rating range without device replacement.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories and Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLateral auxiliary switches (1 NO+1 NC, 2 NO, 2 NC contacts)\u003c\/li\u003e\n\u003cli\u003eTransverse auxiliary switches (1 CO, 1 NO+1 NC, 2 NO contacts)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for remote status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt releases)\u003c\/li\u003e\n\u003cli\u003eSealable cover for setting protection\u003c\/li\u003e\n\u003cli\u003eTerminal blocks and phase barriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with SIRIUS modular system components\u003c\/li\u003e\n\u003cli\u003eDirect mounting capability with contactors via link modules\u003c\/li\u003e\n\u003cli\u003eIntegration with 3-phase busbar systems (3RV1915 series)\u003c\/li\u003e\n\u003cli\u003eCompatible with door-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eSuitable for 3RV2917 infeed system integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSurface-mounting enclosures (IP55\/IP65)\u003c\/li\u003e\n\u003cli\u003eFlush-mounting enclosures (IP55 front, IP20 rear)\u003c\/li\u003e\n\u003cli\u003eFront plates for custom panel integration\u003c\/li\u003e\n\u003cli\u003eCast aluminum and molded plastic enclosure variants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation Considerations\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating Selection:\u003c\/strong\u003e Ideal for motors with rated currents between 10-16A, providing optimal protection without oversizing the protective device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure adequate ventilation and ambient temperature control for optimal performance at maximum current ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Sizing:\u003c\/strong\u003e Use appropriate conductor sizes for the full current range to ensure safe and reliable operation.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/attachments\/60279172\/manual_SIRIUS_circuit_breaker_3RV_en-US.pdf\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAD and Engineering Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003e3D Models and CAD Files\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eDimensional Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eEPLAN Macros\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertificates and Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eProduct Certificates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eDeclaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eSafety Data Sheets\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/tst\"\u003eSelection Tools\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\"\u003eOnline Product Support\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eTechnical Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eConfiguration Guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067330624,"sku":"3RV2011-4AA10","price":1539.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/b2f2ef67989a74082d56516f25d90507.png?v=1743420070"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-163a","title":"Siemens Circuit breaker for motor protection, size S00, 163A","description":"\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e3RV2011-1KA10\u003c\/strong\u003e is a high-performance circuit breaker engineered for motor protection applications requiring maximum current ratings in the S00 size category. This compact device delivers superior overload and short-circuit protection with a CLASS 10 A-release rating of 9...12 A and enhanced N-release of 163 A, featuring reliable screw terminal connections and standard switching capacity for the most demanding industrial applications.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current Protection:\u003c\/strong\u003e Provides comprehensive motor protection with the highest current rating available in S00 size (9...12 A), ideal for larger motors requiring robust protection in a compact form factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Short-Circuit Protection:\u003c\/strong\u003e Features the highest N-release rating of 163 A in the S00 category, providing superior short-circuit protection for demanding applications and high-performance motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Screw Terminal Technology:\u003c\/strong\u003e Proven screw terminal connections ensure secure, long-lasting electrical connections with easy maintenance and inspection capabilities for critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact High-Performance Design:\u003c\/strong\u003e Size S00 form factor (45mm width) delivers maximum protection capability while maintaining space-efficient installation requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Grade Construction:\u003c\/strong\u003e Built for the most demanding industrial environments with superior reliability and consistent performance characteristics.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 9...12 A (adjustable)\u003c\/li\u003e\n\u003cli\u003eShort-circuit release: 163 A (N-release)\u003c\/li\u003e\n\u003cli\u003eRated operational voltage: Up to 690V AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity: 100 kA at 400V AC\u003c\/li\u003e\n\u003cli\u003eRated frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eTripping class: CLASS 10 (IEC 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 45 x 97 x 91 mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.350 kg\u003c\/li\u003e\n\u003cli\u003eTerminal type: Screw terminals (M3)\u003c\/li\u003e\n\u003cli\u003eTightening torque: 0.8-1.2 Nm\u003c\/li\u003e\n\u003cli\u003eProtection rating: IP20\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductor capacity: 2 x (0.75 to 2.5) mm² (solid and stranded)\u003c\/li\u003e\n\u003cli\u003eMaximum: 2 x 4 mm²\u003c\/li\u003e\n\u003cli\u003eAWG wire support: 2 x (18 to 14), 2 x 12\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (0.5 to 2.5) mm²\u003c\/li\u003e\n\u003cli\u003eTool requirement: Pozidriv size PZ 2, Ø 5-6 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -20°C to +60°C (with derating above 60°C)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -50°C to +80°C\u003c\/li\u003e\n\u003cli\u003eInstallation altitude: Up to 2000m\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eHumidity: 95% relative humidity (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1, IEC 60947-2\u003c\/strong\u003e - Low-voltage switchgear and controlgear standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1\u003c\/strong\u003e - Motor starter protector requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1 (UL 508)\u003c\/strong\u003e - North American safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 14\u003c\/strong\u003e - Canadian safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e - Environmental compliance since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking\u003c\/strong\u003e - European conformity declaration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Directive\u003c\/strong\u003e - Take-back obligation compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Motor Protection:\u003c\/strong\u003e Specifically designed for protecting three-phase motors with ratings from 9-12A, providing both overload and short-circuit protection for the largest motors that can be accommodated in S00 size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Industrial Applications:\u003c\/strong\u003e Ideal for use in demanding industrial environments including heavy machinery, large pumps, high-performance conveyor systems, and industrial processing equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCritical System Protection:\u003c\/strong\u003e Perfect for applications where maximum protection is required in a compact form factor, such as critical infrastructure, automated manufacturing systems, and precision industrial equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Applications:\u003c\/strong\u003e Suitable for motors with demanding startup characteristics, high inrush currents, and applications requiring superior short-circuit protection capability.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation and Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eScrew mounting on mounting plate with optional push-in lugs\u003c\/li\u003e\n\u003cli\u003eCompatible with standard industrial control cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecure screw terminal connections for maximum reliability\u003c\/li\u003e\n\u003cli\u003eProper tightening torque essential for optimal performance\u003c\/li\u003e\n\u003cli\u003eRegular inspection recommended for critical applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum clearance from live parts: 30mm (lateral), 9mm (front\/back)\u003c\/li\u003e\n\u003cli\u003eSuitable for side-by-side mounting with appropriate spacing\u003c\/li\u003e\n\u003cli\u003eStand-alone or side-by-side design configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003ePerformance Characteristics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Adjustable current setting from 9-12A provides precise protection for various motor sizes while maintaining CLASS 10 tripping characteristics for reliable operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Enhanced 163A N-release provides superior protection against short-circuit conditions, ensuring safe disconnection and equipment protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Compensation:\u003c\/strong\u003e Temperature-compensated overload release ensures consistent protection across the full operating temperature range (-20°C to +60°C).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Loss Sensitivity:\u003c\/strong\u003e Integrated phase loss detection prevents motor damage from unbalanced supply conditions and phase failures.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories and Compatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLateral auxiliary switches (1 NO+1 NC, 2 NO, 2 NC contacts)\u003c\/li\u003e\n\u003cli\u003eTransverse auxiliary switches (1 CO, 1 NO+1 NC, 2 NO contacts)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for remote status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt releases)\u003c\/li\u003e\n\u003cli\u003eSealable cover for setting protection\u003c\/li\u003e\n\u003cli\u003eTerminal blocks and phase barriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with SIRIUS modular system components\u003c\/li\u003e\n\u003cli\u003eDirect mounting capability with contactors via link modules\u003c\/li\u003e\n\u003cli\u003eIntegration with 3-phase busbar systems (3RV1915 series)\u003c\/li\u003e\n\u003cli\u003eCompatible with door-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eSuitable for 3RV2917 infeed system integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSurface-mounting enclosures (IP55\/IP65)\u003c\/li\u003e\n\u003cli\u003eFlush-mounting enclosures (IP55 front, IP20 rear)\u003c\/li\u003e\n\u003cli\u003eFront plates for custom panel integration\u003c\/li\u003e\n\u003cli\u003eCast aluminum and molded plastic enclosure variants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eSelection Considerations\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Compatibility:\u003c\/strong\u003e Ideal for motors with rated currents between 9-12A, providing optimal protection without oversizing the protective device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Requirements:\u003c\/strong\u003e Best suited for applications requiring maximum protection capability in S00 size, particularly where short-circuit currents may be elevated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Factors:\u003c\/strong\u003e Suitable for indoor industrial environments with proper ventilation and protection from dust and moisture.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/attachments\/60279172\/manual_SIRIUS_circuit_breaker_3RV_en-US.pdf\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAD and Engineering Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003e3D Models and CAD Files\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eDimensional Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eEPLAN Macros\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertificates and Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eProduct Certificates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eDeclaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eSafety Data Sheets\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/tst\"\u003eSelection Tools\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\"\u003eOnline Product Support\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eTechnical Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eConfiguration Guidelines\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497425984,"sku":"3RV2011-1KA10","price":1476.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/cb50c630cf7284d781a5417f9fd1ea9b.png?v=1743420070"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-13a","title":"Siemens Circuit breaker for motor protection, size S00, 13A","description":"\u003cp\u003eCircuit breaker size S00 for motor protection, CLASS 10 A-release 0.7...1 A N-release 13 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3\/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL\/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067297856,"sku":"3RV2011-0JA10","price":1197.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/6118fbe7df199f6d6bf421fb1bca0ae1.png?v=1743420072"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-16a","title":"Siemens Circuit breaker for motor protection, size S00, 16A","description":"\u003cp\u003eThe 3RV2011-0KA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 0.9 to 1.25 A and N-release rated at 16 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 0.9 to 1.25 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 16 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.758 lb (0.344 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 18 to 14 AWG, 12 AWG wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 1.25 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 0.37 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 0.2 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-0KA10 is suitable for protecting medium three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 0.9-1.25 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 0.37 kW at 400V and 0.2 kW at 230V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 16 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.758 lb (0.344 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712409\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643921731\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Rating:\u003c\/strong\u003e 65kA at 480Y\/277V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-0KA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497393216,"sku":"3RV2011-0KA10","price":1269.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/1d23e909ee35ffe71f64fbd41a036793.png?v=1743420072"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-21a","title":"Siemens Circuit breaker for motor protection, size S00, 21A","description":"\u003cp\u003eThe 3RV2011-1AA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 1.1 to 1.6 A and N-release rated at 21 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 1.1 to 1.6 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 21 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.760 lb (0.345 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 1.6 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 0.55 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 0.25 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1AA10 is suitable for protecting medium to larger three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 1.1-1.6 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 0.55 kW at 400V and 0.25 kW at 230V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 21 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.760 lb (0.345 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712416\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643921786\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate-Proof Design:\u003c\/strong\u003e Optimized for use in various environmental conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1AA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497360448,"sku":"3RV2011-1AA10","price":1269.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/a3717b9a96d38c2ee66f37c6adcb3f76.png?v=1743420076"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-42a","title":"Siemens Circuit breaker for motor protection, size S00, 42A","description":"\u003cp\u003eThe 3RV2011-1DA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 2.2 to 3.2 A and N-release rated at 42 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 2.2 to 3.2 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 42 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Temperature Range:\u003c\/strong\u003e -50°C to +80°C operational capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.767 lb (0.348 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 3.2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 1.1 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 0.55 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection Range:\u003c\/strong\u003e Up to 55\/45 kW at 400 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1DA10 is suitable for protecting larger three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 2.2-3.2 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 1.1 kW at 400V and 0.55 kW at 230V in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 42 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.767 lb (0.348 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712447\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643921939\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate-Proof Design:\u003c\/strong\u003e Optimized for use in various environmental conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Operating Range:\u003c\/strong\u003e Suitable for demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2011-1DA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067265088,"sku":"3RV2011-1DA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/140c46204a1a138582c86848243c5308.png?v=1743420076"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-52a","title":"Siemens Circuit breaker for motor protection, size S00, 52A","description":"\u003cp\u003eThe 3RV2011-1EA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 2.8 to 4 A and N-release rated at 52 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 2.8 to 4 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 52 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.763 lb (0.346 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC (600V UL rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 1.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 0.75 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch-off Technique:\u003c\/strong\u003e Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Yes, with bimetallic heating elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1EA10 is suitable for protecting larger three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 2.8-4 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 1.5 kW at 400V and 0.75 kW at 230V in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 52 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection and provides over-current protection for both AC and DC motors. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.763 lb (0.346 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712454\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643923926\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate-Proof Design:\u003c\/strong\u003e Optimized for use in various environmental conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1EA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067199552,"sku":"3RV2011-1EA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/f074fb49e8f4e22b2e1ee5e822db2961.png?v=1743420079"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-26a","title":"Siemens Circuit breaker for motor protection, size S00, 26A","description":"\u003cp\u003eCircuit breaker size S00 for motor protection, CLASS 10 A-release 1.4...2 A N-release 26 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, these compact and climate-proof circuit breakers are optimized for use in load feeders, as well as for IE3\/IE4 motors, of course. Worldwide approvals (e.g. IEC and UL\/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067166784,"sku":"3RV2011-1BA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/de3a20e509a49578efd89175946bdd27.png?v=1743420079"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-8-2a","title":"Siemens Circuit breaker for motor protection, size S00, 8.2A","description":"\u003cp\u003eThe 3RV2011-0GA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 0.45 to 0.63 A and N-release rated at 8.2 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for low-current three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 0.45 to 0.63 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 8.2 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.615 lb (0.279 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection Range:\u003c\/strong\u003e Up to 55\/45 kW at 400 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-0GA10 is suitable for protecting small to medium three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 0.45-0.63 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 0.63 A rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 8.2 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.615 lb (0.279 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712379\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643921588\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-0GA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497294912,"sku":"3RV2011-0GA10","price":1125.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/d4cebaf1d05982af738233ddd2f03d14.png?v=1743420083"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s2-585a","title":"Siemens Circuit breaker for motor protection, size S2, 585A","description":"\u003cp\u003eThe SIRIUS circuit breaker 3RV2031-4UA10 from Siemens in size S2 is a compact, current-limiting circuit breaker for load feeders up to 18.5 kW at AC-3\/400 V. Due to a short-circuit protection of 585 A and an adjustable overload protection of 32-40 A, the circuit breaker is ideally suited for the protection of motors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497262144,"sku":"3RV2031-4UA10","price":3996.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/e1b35cf677d0f90e60791efb966b111f.png?v=1743420082"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-82a","title":"Siemens Circuit breaker for motor protection, 82A, size S00","description":"\u003cdiv style=\"border: 0px solid; box-sizing: border-box; --tw-border-spacing-x: 0; --tw-border-spacing-y: 0; --tw-translate-x: 0; --tw-translate-y: 0; --tw-rotate: 0; --tw-skew-x: 0; --tw-skew-y: 0; --tw-scale-x: 1; --tw-scale-y: 1; --tw-scroll-snap-strictness: proximity; --tw-ring-offset-width: 0px; --tw-ring-offset-color: #fff; --tw-ring-color: hsl(var(--accent-secondary-100)\/1); --tw-ring-offset-shadow: 0 0 #0000; --tw-ring-shadow: 0 0 #0000; --tw-shadow: 0 0 #0000; --tw-shadow-colored: 0 0 #0000; outline-color: hsl(var(--accent-secondary-100)); scrollbar-width: thin; scrollbar-color: hsla(var(--border-300)\/35%) transparent; display: grid; grid-template-columns: repeat(1, minmax(0px, 1fr)); gap: 0.625rem;\"\u003e\n\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3RV2011-1GA10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered circuit breaker designed for motor protection applications. This size S00 device offers reliable overload and short-circuit protection with a CLASS 10 A-release rating of 4.5...6.3 A and N-release of 82 A, featuring screw terminal connections and standard switching capacity.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides comprehensive motor protection with integrated overload and short-circuit releases, ensuring safe operation and equipment longevity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSize S00 form factor (45mm width) offers space-efficient installation while maintaining full protection capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for motor protection, system protection, and various industrial control applications up to 690V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN rail mounting with screw terminal connections supports conductors from 0.75 to 2.5 mm² (solid and stranded).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCLASS 10 tripping characteristics ensure consistent protection according to IEC 60947-4-1 standards.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current: 4.5...6.3 A (adjustable)\u003c\/li\u003e\n\u003cli\u003eRated operational voltage: Up to 690V AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity: 100 kA at 400V AC\u003c\/li\u003e\n\u003cli\u003eRated frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProtection class: IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 45 x 97 x 91 mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.352 kg\u003c\/li\u003e\n\u003cli\u003eTerminal type: Screw terminals (M3)\u003c\/li\u003e\n\u003cli\u003eTightening torque: 0.8-1.2 Nm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -50°C to +80°C\u003c\/li\u003e\n\u003cli\u003eAltitude: Up to 2000m\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1, IEC 60947-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Low-voltage switchgear standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-4-1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Motor starter protector requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60947-4-1 (UL 508)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- North American safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Environmental compliance since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- European conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for protecting three-phase motors in industrial applications, providing both overload and short-circuit protection in a single device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with SIRIUS modular system components including contactors, overload relays, and soft starters for complete motor control solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Controls:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for use in control panels, distribution boards, and industrial automation systems requiring reliable motor protection.\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation and Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting (standard)\u003c\/li\u003e\n\u003cli\u003eScrew mounting on mounting plate\u003c\/li\u003e\n\u003cli\u003eCompatible with standard control cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConnection System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScrew terminal technology for reliable connections\u003c\/li\u003e\n\u003cli\u003eSupports up to 2 x 2.5 mm² conductors\u003c\/li\u003e\n\u003cli\u003eAWG wire support: 2 x (18 to 14), 2 x 12\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum clearance from live parts: 30mm (sides), 9mm (front\/back)\u003c\/li\u003e\n\u003cli\u003eSuitable for side-by-side mounting with appropriate spacing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories and Options\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuxiliary switches (lateral and transverse mounting)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for remote monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt)\u003c\/li\u003e\n\u003cli\u003eTerminal blocks and phase barriers\u003c\/li\u003e\n\u003cli\u003eEnclosures for surface and flush mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect mounting with SIRIUS contactors via link modules\u003c\/li\u003e\n\u003cli\u003eIntegration with 3-phase busbar systems\u003c\/li\u003e\n\u003cli\u003eCompatible with door-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Documentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/attachments\/60279172\/manual_SIRIUS_circuit_breaker_3RV_en-US.pdf\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCAD and Engineering Data:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003e3D Models and CAD Files\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eDimensional Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eEPLAN Macros\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertificates and Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eProduct Certificates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/cert\"\u003eDeclaration of Conformity\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/tst\"\u003eSelection Tools\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\"\u003eOnline Product Support\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/16244\/td\"\u003eTechnical Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40419067101248,"sku":"3RV2011-1GA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/282ec6a43fc552171a824e74f097fb22.png?v=1743420085"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s2-1040a","title":"Siemens Circuit breaker for motor protection, size S2, 1040A","description":"\u003cdiv\u003e\n\u003cp\u003eCircuit breaker size S2 for motor protection, CLASS 10 A-release 70...80 A N-release 1040 A screw terminal Standard switching capacity\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S2 (55 mm width)\u003c\/li\u003e\n\u003cli\u003eCurrent Range: 70...80 A adjustable thermal overload release\u003c\/li\u003e\n\u003cli\u003eShort-circuit Release: 1040 A (N-release)\u003c\/li\u003e\n\u003cli\u003eTrip Class: CLASS 10 according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eConnection System: Screw-type terminal\u003c\/li\u003e\n\u003cli\u003eNumber of Poles: 3-pole\u003c\/li\u003e\n\u003cli\u003eRated Operational Voltage: Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003eRated Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 508, CSA C22.2 No. 14\u003c\/li\u003e\n\u003cli\u003eISO 13849, IEC 61508 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Temperature: -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -50°C to +80°C\u003c\/li\u003e\n\u003cli\u003eDegree of Protection: IP20\u003c\/li\u003e\n\u003cli\u003eInstallation Altitude: Maximum 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 10-95% during operation\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.18 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase failure detection for reliable motor protection\u003c\/li\u003e\n\u003cli\u003eIntegrated overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eON\/OFF rotary handle with lockout capability\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity up to 65 kA at 240V\/400V AC\u003c\/li\u003e\n\u003cli\u003eMechanical service life: 20,000 operating cycles\u003c\/li\u003e\n\u003cli\u003ePower loss: 29.5 W at AC in hot operating state\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminal Connection System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTool Required: Pozidriv size 2 screwdriver\u003c\/li\u003e\n\u003cli\u003eTightening Torque: 3-4.5 N·m for main contacts\u003c\/li\u003e\n\u003cli\u003eThread Design: M6 for main contacts\u003c\/li\u003e\n\u003cli\u003eConductor Cross-sections: 2 x (1 to 35) mm², 1 x (1 to 50) mm²\u003c\/li\u003e\n\u003cli\u003eAWG cables: 2 x (18 to 2), 1 x (18 to 1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor protection for three-phase motors (60-75 HP range)\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection for high-power applications\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eSuitable for motors with rated currents between 70-80 A\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial applications\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient IE3 motor applications\u003c\/li\u003e\n\u003cli\u003eLarge industrial machinery and equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Power Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e230V AC: 22 kW (30 HP)\u003c\/li\u003e\n\u003cli\u003e400V AC: 37 kW (50 HP)\u003c\/li\u003e\n\u003cli\u003e500V AC: 55 kW (75 HP)\u003c\/li\u003e\n\u003cli\u003e690V AC: 75 kW (100 HP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUL\/CSA Motor Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200\/208V: 25 HP\u003c\/li\u003e\n\u003cli\u003e220\/230V: 30 HP\u003c\/li\u003e\n\u003cli\u003e460\/480V: 60 HP\u003c\/li\u003e\n\u003cli\u003e575\/600V: 75 HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: 35 mm DIN rail according to DIN EN 60715\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions: 62.00 x 147.00 x 167.00 mm\u003c\/li\u003e\n\u003cli\u003eDevice Dimensions: 140 x 55 x 149 mm\u003c\/li\u003e\n\u003cli\u003eSide-by-side mounting capability with 0 mm spacing\u003c\/li\u003e\n\u003cli\u003eTop and bottom terminal arrangement\u003c\/li\u003e\n\u003cli\u003eAny mounting position acceptable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Germany\u003c\/li\u003e\n\u003cli\u003eRoHS Compliance: Since 10.04.2015\u003c\/li\u003e\n\u003cli\u003eUL\/CSA Approvals: Available for North American applications\u003c\/li\u003e\n\u003cli\u003eKC Approval: For Korean market applications\u003c\/li\u003e\n\u003cli\u003eMaritime Application: Certified for marine environments\u003c\/li\u003e\n\u003cli\u003eREACH Regulation: Contains lead and lead titanium zirconium oxide \u0026gt;0.1% w\/w\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Protection Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents motor damage from overload conditions\u003c\/li\u003e\n\u003cli\u003eProtects against phase loss and unbalanced loads\u003c\/li\u003e\n\u003cli\u003eExtends motor life through precise current monitoring\u003c\/li\u003e\n\u003cli\u003eSuperior N-release rating (1040A) for high-power applications\u003c\/li\u003e\n\u003cli\u003eCLASS 10 trip characteristics for consistent performance\u003c\/li\u003e\n\u003cli\u003eTemperature compensated operation across wide ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Protection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtended Current Range: 70-80A suitable for large motors\u003c\/li\u003e\n\u003cli\u003eSuperior Short-Circuit Protection: 1040A N-release for maximum safety\u003c\/li\u003e\n\u003cli\u003eReliable Trip Characteristics: CLASS 10 tripping for consistent performance\u003c\/li\u003e\n\u003cli\u003ePhase Loss Detection: Protects against unbalanced load conditions\u003c\/li\u003e\n\u003cli\u003eMagnetic Trip Elements: Fast response to short-circuit conditions\u003c\/li\u003e\n\u003cli\u003eThermal Overload Protection: Accurate thermal protection for motors\u003c\/li\u003e\n\u003cli\u003eSafety Function: Suitable for safety-related switching OFF applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RV2031-4RA10\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"http:\/\/www.automation.siemens.com\/bilddb\/cax_de.aspx?mlfb=3RV2031-4RA10\u0026amp;lang=en\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"http:\/\/support.automation.siemens.com\/WW\/CAXorder\/default.aspx?lang=en\u0026amp;mlfb=3RV2031-4RA10\"\u003eCAD Data\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"http:\/\/www.automation.siemens.com\/bilddb\/cax_de.aspx?mlfb=3RV2031-4RA10\u0026amp;lang=en\"\u003e3D Models\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/3RV2031-4RA10\"\u003eProduct Support Portal\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/ps\/3RV2031-4RA10\/char\"\u003eTripping Characteristics\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2031-4RA10\"\u003eIndustry Mall\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/ic10\"\u003eSIRIUS System Overview\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"h-8\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554971402304,"sku":"3RV2031-4RA10","price":5445.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2031-4RA10.jpg?v=1743420084"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s2-741a","title":"Siemens Circuit breaker for motor protection, size S2, 741A","description":"\u003cp\u003eThe SIRIUS circuit breaker 3RV2031-4WA10 from Siemens in size S2 is a compact, current-limiting circuit breaker for load feeders up to 22 kW at AC-3\/400 V. Due to a short-circuit protection of 741 A and an adjustable overload protection of 42 - 52 A, the circuit breaker is ideally suited for the protection of motors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554971533376,"sku":"3RV2031-4WA10","price":4518.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2031-4WA10.jpg?v=1743420088"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s3-975a","title":"Siemens Circuit breaker for motor protection, size S3, 975A","description":"\u003cp\u003eThe SIRIUS circuit breaker 3RV2041-4KA10 from Siemens in size S3 is a compact, current-limiting circuit breaker for load feeders up to 37 kW at AC-3\/400 V. Due to a short-circuit protection of 975 A and an adjustable overload protection of 57-75 A, the circuit breaker is ideally suited for the protection of motors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413497229376,"sku":"3RV2041-4KA10","price":4878.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/a1ddcac0ea4aee444318d4f9edb6aa0d.png?v=1743420095"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s3-520a","title":"Siemens Circuit breaker for motor protection, size S3, 520A","description":"\u003cp\u003eThe SIRIUS circuit breaker 3RV2041-4FA10 from Siemens in size S3 is a compact, current-limiting circuit breaker for load feeders up to 18.5 kW at AC-3\/400 V. Due to a short-circuit protection of 520 A and an adjustable overload protection of 28 - 40 A, the circuit breaker is ideally suited for the protection of motors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554971893824,"sku":"3RV2041-4FA10","price":4374.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2041-4FA10.jpg?v=1743420097"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s0-34-40a","title":"Siemens Overload relay for motor protection, size S0, 34-40A","description":"\u003cp\u003eThe 3RU2126-4FB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S0, Class 10 relay features an adjustable current range of 34 to 40 A and is optimized for direct mounting on Siemens 3RT2 size 0 contactors (9 to 38 AMPS) to provide reliable motor protection for the highest current applications in the S0 series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 34 to 40 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 for larger motor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2 size 0 contactors (9-38A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 85mm H x 45mm W x 85mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.200 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 40A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e UL rated, RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 18.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 6W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2126-4FB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required for very high current motor systems. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations requiring the highest current protection in the Size S0 range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.200 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209781009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643919424\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL, CSA, CCC, EAC, CE, EX, IECEX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4FB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4FB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4FB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978644032,"sku":"3RU2126-4FB0","price":1593.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2126-4FB0.jpg?v=1743420251"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s0-20-25a","title":"Siemens Overload relay for motor protection, size S0, 20-25A","description":"\u003cp\u003eThe 3RU2126-4DB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S0, Class 10 relay features an adjustable current range of 20 to 25 A and is optimized for direct mounting on Siemens 3RT2 size 0 contactors (9 to 38 AMPS) to provide reliable motor protection for high current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 20 to 25 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 for larger motor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2 size 0 contactors (9-38A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 85mm H x 45mm W x 85mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.192 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 25A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e UL rated, RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 11 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 6W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2126-4DB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required for high current motor systems. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.192 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209780965\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643919325\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL, CSA, CCC, EAC, CE, EX, IECEX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4DB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4DB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4DB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978709568,"sku":"3RU2126-4DB0","price":1035.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2126-4DB0.jpg?v=1743420255"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s0-14-20a","title":"Siemens Overload relay for motor protection, size S0, 14-20A","description":"\u003cp\u003eThe 3RU2126-4BB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S0, Class 10 relay features an adjustable current range of 14 to 20 A and is optimized for direct mounting on Siemens 3RT2 size 0 contactors (9 to 38 AMPS) to provide reliable motor protection for higher current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 14 to 20 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 for larger motor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2 size 0 contactors (9-38A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 85mm H x 45mm W x 85mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.193 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 20A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e UL rated, RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 7.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 6W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2126-4BB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required for medium to high current motor systems. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.193 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209780941\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643919226\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL, CSA, CCC, EAC, CE, EX, IECEX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4BB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4BB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2126-4BB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978676800,"sku":"3RU2126-4BB0","price":1035.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2126-4BB0.jpg?v=1743420254"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s0-27-32a","title":"Siemens Overload relay for motor protection, size S0, 27-32A","description":"\u003cp\u003eThe 3RU2126-4EB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S0, Class 10 relay features an adjustable current range of 27 to 32 A and is optimized for direct mounting on Siemens 3RT2 size 0 contactors (9 to 38 AMPS) to provide reliable motor protection for very high current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 27 to 32 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 for larger motor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2 size 0 contactors (9-38A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 85mm H x 45mm W x 85mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.210 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 32A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e UL rated, RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 15 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 6W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2126-4EB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required for very high current motor systems. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.210 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209780989\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643919370\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL, CSA, CCC, EAC, CE, EX, IECEX\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4EB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4EB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2126-4EB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978775104,"sku":"3RU2126-4EB0","price":1593.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2126-4EB0.jpg?v=1743420258"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-0-45-0-63a","title":"Siemens Overload relay for motor protection, size S00, 0.45-0.63A","description":"\u003cp\u003eOverload relay 0.45...0.63 A thermal for motor protection, Size S00, Class 10, contactor mounting, main circuit: screw, auxiliary circuit: screw, manual-automatic-reset. Article Number: 3RU2116-0GB0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent range: 0.45-0.63 A\u003c\/li\u003e\n\u003cli\u003eProtection type: Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n\u003cli\u003eClass: 10\u003c\/li\u003e\n\u003cli\u003eReset function: Manual-Automatic-Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S00 (compact design)\u003c\/li\u003e\n\u003cli\u003eMounting: Contactor mounting\u003c\/li\u003e\n\u003cli\u003eMain circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eThermal protection technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 0.157 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 49 × 102 × 84 mm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEAN: 4011209781559\u003c\/li\u003e\n\u003cli\u003eUPC: 662643919899\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant since 01.10.2009\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligation: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREACH Regulation Information\u003c\/strong\u003e This product contains the following substance from the candidate list in concentrations higher than 0.1% weight by weight (w\/w):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBased on currently available information, this substance does not pose any risk if the article is used as intended (including disposal). Please refer to product documentation for additional details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RU2116-0GB0\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0GB0\"\u003eCAD Drawings \u0026amp; Technical Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0GB0\/therm-overload-relay-0-45-0-63-a\"\u003eCertificates\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978807872,"sku":"3RU2116-0GB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2116-0GB0.jpg?v=1743420257"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-0-70-1a","title":"Siemens Overload relay for motor protection, size S00, 0.70-1A","description":"\u003cp\u003eOverload relay 0.70...1.0 A thermal for motor protection, Size S00, Class 10, contactor mounting, main circuit: screw, auxiliary circuit: screw, manual-automatic-reset. Article Number: 3RU2116-0JB0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent range: 0.70-1.0 A\u003c\/li\u003e\n\u003cli\u003eProtection type: Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n\u003cli\u003eClass: 10\u003c\/li\u003e\n\u003cli\u003eReset function: Manual-Automatic-Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S00 (compact design)\u003c\/li\u003e\n\u003cli\u003eMounting: Contactor mounting\u003c\/li\u003e\n\u003cli\u003eMain circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eThermal protection technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 0.154 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 49 × 102 × 84 mm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEAN: 4011209781573\u003c\/li\u003e\n\u003cli\u003eUPC: 662643919998\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant since 01.10.2009\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligation: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREACH Regulation Information\u003c\/strong\u003e This product contains the following substance from the candidate list in concentrations higher than 0.1% weight by weight (w\/w):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBased on currently available information, this substance does not pose any risk if the article is used as intended (including disposal). Please refer to product documentation for additional details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RU2116-0JB0\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0JB0\"\u003eCAD Drawings \u0026amp; Technical Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0JB0\/therm-overload-relay-0-70-1-0-a\"\u003eCertificates\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413496803392,"sku":"3RU2116-0JB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/65558677b498ba064314361d2a82f480.png?v=1743420261"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-1-4-2a","title":"Siemens Overload relay for motor protection, size S00, 1.4-2A","description":"\u003cp\u003eSiemens thermal overload relay, 3RU2116-1BB0 is the perfect fit for current-dependent overload protection in the main circuit. The thermal overload relay offers a wide setting range of 1.4-2 A. The SIRIUS overload relay provides an excellent safeguard for motors and systems up to 0.75 kW. The thermal overload relay is designed to effortlessly be inserted into any load feeder due to its optimised size S00 as well as a screw connection.\u003c\/p\u003e\n\u003cp\u003eMonitoring relays are used in all areas of electrical switchgear technology.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978873408,"sku":"3RU2116-1BB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2116-1BB0.jpg?v=1743420260"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-0-90-1-25a","title":"Siemens Overload relay for motor protection, size S00, 0.90-1.25A","description":"\u003cp\u003eOverload relay 0.90...1.25 A thermal for motor protection, Size S00, Class 10, contactor mounting, main circuit: screw, auxiliary circuit: screw, manual-automatic-reset. Article Number: 3RU2116-0KB0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent range: 0.90-1.25 A\u003c\/li\u003e\n\u003cli\u003eProtection type: Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n\u003cli\u003eClass: 10\u003c\/li\u003e\n\u003cli\u003eReset function: Manual-Automatic-Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S00 (compact design)\u003c\/li\u003e\n\u003cli\u003eMounting: Contactor mounting\u003c\/li\u003e\n\u003cli\u003eMain circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eThermal protection technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 0.150 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 49 × 102 × 84 mm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEAN: 4011209781580\u003c\/li\u003e\n\u003cli\u003eUPC: 662643920048\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant since 01.10.2009\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligation: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREACH Regulation Information\u003c\/strong\u003e This product contains the following substance from the candidate list in concentrations higher than 0.1% weight by weight (w\/w):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBased on currently available information, this substance does not pose any risk if the article is used as intended (including disposal). Please refer to product documentation for additional details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RU2116-0KB0\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0KB0\"\u003eCAD Drawings \u0026amp; Technical Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-0KB0\/overload-relay-thermal-motor-protection-s00-class10\"\u003eCertificates\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554978906176,"sku":"3RU2116-0KB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2116-0KB0.jpg?v=1743420263"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-1-1-1-6a","title":"Siemens Overload relay for motor protection, size S00, 1.1-1.6A","description":"\u003cp\u003eOverload relay 1.1...1.6 A thermal for motor protection, Size S00, Class 10, contactor mounting, main circuit: screw, auxiliary circuit: screw, manual-automatic-reset. Article Number: 3RU2116-1AB0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent range: 1.1-1.6 A\u003c\/li\u003e\n\u003cli\u003eProtection type: Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n\u003cli\u003eClass: 10\u003c\/li\u003e\n\u003cli\u003eReset function: Manual-Automatic-Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S00 (compact design)\u003c\/li\u003e\n\u003cli\u003eMounting: Contactor mounting\u003c\/li\u003e\n\u003cli\u003eMain circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eThermal protection technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 0.160 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 49 × 102 × 84 mm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEAN: 4011209781597\u003c\/li\u003e\n\u003cli\u003eUPC: 662643920093\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant since 01.10.2009\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligation: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREACH Regulation Information\u003c\/strong\u003e This product contains the following substance from the candidate list in concentrations higher than 0.1% weight by weight (w\/w):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBased on currently available information, this substance does not pose any risk if the article is used as intended (including disposal). Please refer to product documentation for additional details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RU2116-1AB0\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-1AB0\"\u003eCAD Drawings \u0026amp; Technical Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-1AB0\/overload-relay-thermal-motor-protection-s00-class10\"\u003eCertificates\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413496770624,"sku":"3RU2116-1AB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/e0cce939ddf84a2e119f0396d6c7ddeb.png?v=1743420264"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-9-12-5a","title":"Siemens Overload relay for motor protection, size S00, 9-12.5A","description":"\u003cp\u003eThe 3RU2116-1KB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S00, Class 10 relay features an adjustable current range of 9.0 to 12.5 A and is optimized for direct mounting on Siemens 3RT contactors to save space while providing reliable motor protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 9.0 to 12.5 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2015 through 3RT2018 contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 76mm H x 45mm W x 70mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.154 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 12.5A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 5.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2116-1KB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.154 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 84.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209781689\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643918854\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1KB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1KB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1KB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554979037248,"sku":"3RU2116-1KB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2116-1KB0.jpg?v=1743420266"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-2-2-3-2a","title":"Siemens Overload relay for motor protection, size S00, 2.2-3.2A","description":"\u003cp\u003eOverload relay 1.1...1.6 A thermal for motor protection, Size S00, Class 10, contactor mounting, main circuit: screw, auxiliary circuit: screw, manual-automatic-reset. Article Number: 3RU2116-1AB0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent range: 1.1-1.6 A\u003c\/li\u003e\n\u003cli\u003eProtection type: Thermal overload protection\u003c\/li\u003e\n\u003cli\u003eApplication: Motor protection\u003c\/li\u003e\n\u003cli\u003eClass: 10\u003c\/li\u003e\n\u003cli\u003eReset function: Manual-Automatic-Reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSize: S00 (compact design)\u003c\/li\u003e\n\u003cli\u003eMounting: Contactor mounting\u003c\/li\u003e\n\u003cli\u003eMain circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit: Screw terminal connections\u003c\/li\u003e\n\u003cli\u003eThermal protection technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet weight: 0.160 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 49 × 102 × 84 mm\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEAN: 4011209781597\u003c\/li\u003e\n\u003cli\u003eUPC: 662643920093\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS compliant since 01.10.2009\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligation: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eREACH Regulation Information\u003c\/strong\u003e This product contains the following substance from the candidate list in concentrations higher than 0.1% weight by weight (w\/w):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBased on currently available information, this substance does not pose any risk if the article is used as intended (including disposal). Please refer to product documentation for additional details.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RU2116-1AB0\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-1AB0\"\u003eCAD Drawings \u0026amp; Technical Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RU2116-1AB0\/overload-relay-thermal-motor-protection-s00-class10\"\u003eCertificates\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413496737856,"sku":"3RU2116-1DB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/0183b64793a60e1c964a938e205d5b2e.png?v=1743420267"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-11-16a","title":"Siemens Overload relay for motor protection, size S00, 11-16A","description":"\u003cp\u003eThe 3RU2116-4AB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S00, Class 10 relay features an adjustable current range of 11 to 16 A and is optimized for direct mounting on Siemens 3RT contactors to save space while providing reliable motor protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 11 to 16 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2015 through 3RT2018 contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 76mm H x 45mm W x 70mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.159 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 16A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 7.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 6.3W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2116-4AB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.159 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 84.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209781696\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643918908\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RU2116-4AB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RU2116-4AB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RU2116-4AB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413496705088,"sku":"3RU2116-4AB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/b6df8cea314fe951051e7f1d87e2e448.png?v=1743420276"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s00-5-5-8a","title":"Siemens Overload relay for motor protection, size S00, 5.5-8A","description":"\u003cp\u003eThe 3RU2116-1HB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S00, Class 10 relay features an adjustable current range of 5.5 to 8.0 A and is optimized for direct mounting on Siemens 3RT contactors to save space while providing reliable motor protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 5.5 to 8.0 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT2015 through 3RT2018 contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 76mm H x 45mm W x 70mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.159 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 8A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e RoHS compliant, meets IEC standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 3 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2116-1HB0 is suitable for protecting motors and electrical loads in industrial applications where reliable overload protection is required. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions and frequency converter operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions for enhanced functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.159 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 49.00 x 102.00 x 84.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209781665\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643920444\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 01.10.2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1HB0\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.downloads.siemens.com\/download-center\/\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1HB0\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RU2116-1HB0\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554979233856,"sku":"3RU2116-1HB0","price":963.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2116-1HB0.jpg?v=1743420274"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s2-54-65a","title":"Siemens Overload relay for motor protection, size S2, 54-65A","description":"\u003cdiv class=\"flex min-h-screen w-full overflow-x-clip\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"flex flex-1 h-screen w-full overflow-hidden relative\"\u003e\n\u003cdiv class=\"max-md:absolute top-0 right-0 bottom-0 left-0 z-20 md:flex-grow-0 md:flex-shrink-0 md:basis-0 overflow-hidden h-screen max-md:flex-1\"\u003e\n\u003cdiv class=\"flex flex-col h-full overflow-hidden\"\u003e\n\u003cdiv class=\"flex-1 overflow-hidden h-full bg-bg-100\"\u003e\n\u003cdiv class=\"bg-bg-000 flex h-full flex-col relative\"\u003e\n\u003cdiv class=\"w-full h-full relative\"\u003e\n\u003cdiv tabindex=\"0\"\u003e\n\u003cdiv id=\"markdown-artifact\" class=\"font-claude-message mx-auto w-full max-w-3xl leading-[1.65rem] -tracking-[0.015em] px-6 pt-4 md:pt-6 md:px-11\" tabindex=\"0\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"flex min-h-screen w-full overflow-x-clip\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"flex flex-1 h-screen w-full overflow-hidden relative\"\u003e\n\u003cdiv class=\"max-md:absolute top-0 right-0 bottom-0 left-0 z-20 md:flex-grow-0 md:flex-shrink-0 md:basis-0 overflow-hidden h-screen max-md:flex-1\"\u003e\n\u003cdiv class=\"flex flex-col h-full overflow-hidden\"\u003e\n\u003cdiv class=\"flex-1 overflow-hidden h-full bg-bg-100\"\u003e\n\u003cdiv class=\"bg-bg-000 flex h-full flex-col relative\"\u003e\n\u003cdiv class=\"w-full h-full relative\"\u003e\n\u003cdiv tabindex=\"0\"\u003e\n\u003cdiv id=\"markdown-artifact\" class=\"font-claude-message mx-auto w-full max-w-3xl leading-[1.65rem] -tracking-[0.015em] px-6 pt-4 md:pt-6 md:px-11\" tabindex=\"0\"\u003e\n\u003cdiv\u003e\n\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003eProduct Overview\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number: 3RU2136-4JB0\u003c\/strong\u003e - SIRIUS 3RU2136-4JB0 thermal overload relay for mounting on Sirius 3RT203 size S2 contactors (3RT2037 and 3RT2038) and is adjustable from 54A-65A. This Class 10 overload (trips in 10 seconds or less) has phase loss protection, manual or automatic reset and two auxiliary contacts, one normally open and one normally closed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent setting range: 54-65 A\u003c\/li\u003e\n\u003cli\u003eFrame size: S2\u003c\/li\u003e\n\u003cli\u003eTrip class: CLASS 10\u003c\/li\u003e\n\u003cli\u003ePhase failure protection: Yes\u003c\/li\u003e\n\u003cli\u003eReset options: Manual\/Automatic\u003c\/li\u003e\n\u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n\u003cli\u003eMain circuit connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 0.34 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePhase loss protection for the purpose of minimizing the heating of the load during single-phase operation as a result of phase failure\u003c\/li\u003e\n\u003cli\u003eSwitch position indicator and TEST function\u003c\/li\u003e\n\u003cli\u003eSTOP button for emergency disconnection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation according to IEC 60947-4-1\/DIN VDE 0660 Part 102\u003c\/li\u003e\n\u003cli\u003eManual and automatic reset functionality\u003c\/li\u003e\n\u003cli\u003eSealable transparent cover (optional accessory)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Designed for thermal overload protection of three-phase and single-phase AC and DC motors. The 3RU2136 thermal overload relays are suitable for direct mounting on the 3RT203 contactors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient temperature: -20°C to +60°C (with temperature compensation)\u003c\/li\u003e\n\u003cli\u003eTrip characteristics: Inverse time-delayed according to CLASS 10\u003c\/li\u003e\n\u003cli\u003eIt is possible to switch between manual resetting and automatic resetting by depressing and rotating the blue button (RESET button).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Direct mounting on Size S2 contactors (3RT2037, 3RT2038) or stand-alone installation with terminal bracket accessory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 60947-1\/DIN VDE 0660 Part 100\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\/DIN VDE 0660 Part 102\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\/DIN VDE 0660 Part 200\u003c\/li\u003e\n\u003cli\u003eUL 508\/CSA C 22.2\u003c\/li\u003e\n\u003cli\u003eEEx e increased safety type protection certification available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Properties:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNet Weight: 0.344 kg\u003c\/li\u003e\n\u003cli\u003ePackaging Dimension: 61.00 x 96.00 x 111.00 mm\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003eDownload existing graphical data for this product:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/830\/35681830\/att_96300\/v1\/lv1t_052_en_2011_04.pdf\"\u003eTechnical Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/60298164\/equipment-manual-sirius-3ru-thermal-overload-relays-3rb-electronic-overload-relays\"\u003eEquipment Manual - SIRIUS 3RU Thermal Overload Relays\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/assets.new.siemens.com\/siemens\/assets\/api\/uuid:db98727f-1c3d-43cb-ab6e-2055705305b4\/version:1557325577\/ic17-sect-03-rev031519.pdf\"\u003eOverload Relays Catalog Section\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/view\/20357046\/133200\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554979332160,"sku":"3RU2136-4JB0","price":2421.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2136-4JB0.jpg?v=1743420278"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s2-28-40a","title":"Siemens Overload relay for motor protection, size S2, 28-40A","description":"\u003cp\u003eThe 3RU2136-4FB0 thermal overload relay is designed for current-dependent protection of three-phase motors and electrical loads against overload, phase asymmetry, and phase failure. This Size S2, Class 10 relay features an adjustable current range of 28 to 40 A and is optimized for direct mounting on Siemens 3RT203 size S2 contactors (3RT2035, 3RT2036, 3RT2037, and 3RT2038) to provide reliable motor protection for high-power industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 28 to 40 A adjustment range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e Class 10 tripping characteristic for fast response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S2 for heavy-duty motor applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Contactor mounting, compatible with 3RT203 size S2 contactors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals for both main and auxiliary circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e 1 normally open (NO) + 1 normally closed (NC) contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Manual or automatic reset capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e IP20 for standard industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 105mm H x 55mm W x 117mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.322 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e 40A at 690VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping Time:\u003c\/strong\u003e Less than 10 seconds at overload conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e IEC rated, RoHS compliant, meets international standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 22 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Voltage:\u003c\/strong\u003e 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpulse Voltage Resistance:\u003c\/strong\u003e 6 kV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e 8W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e The 3RU2136-4FB0 is suitable for protecting motors and electrical loads in heavy-duty industrial applications where reliable overload protection is required for high-power motor systems. It provides inverse time-delayed protection against excessive temperature rises due to overload or phase failure, making it ideal for applications with normal starting conditions, frequency converter operations, and demanding industrial environments requiring Size S2 protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e When an overload or phase failure occurs, the motor current rises above the set rated current. This current increase heats up the bimetal strips within the relay via heating elements, causing them to bend and trigger the auxiliary contacts through a tripping mechanism. The auxiliary contacts then switch off the load via a contactor, with the tripped status indicated by a switch position indicator. The relay features both TEST and STOP functions, and allows switching between manual and automatic reset by depressing and rotating the blue RESET button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.322 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 61.00 x 96.00 x 111.00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209916739\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 887621919566\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 15.10.2014)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2136-4FB0\" class=\"underline\"\u003eProduct Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.downloads.siemens.com\/download-center\/\" class=\"underline\"\u003eTechnical Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2136-4FB0\" class=\"underline\"\u003eCAD Data and Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047449?activeTab=product\" class=\"underline\"\u003eSIRIUS 3RU2 Product Family\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RU2136-4FB0\" class=\"underline\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413496672320,"sku":"3RU2136-4FB0","price":1764.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/products\/796f826aa8861f145d387697855edbf7.png?v=1743420281"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s2-40-50a","title":"Siemens Overload relay for motor protection, size S2, 40-50A","description":"\u003cp\u003eSiemens thermal overload relay, 3RU2136-4HB0 is the perfect fit for current-dependent overload protection in the main circuit. The thermal overload relay offers a wide setting range of 40 - 50 A. The SIRIUS overload relay provides an excellent safeguard for motors and systems. The thermal overload relay is designed to effortlessly be inserted due to its optimised size S2 as well as a Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset.\u003c\/p\u003e\n\u003cp\u003eMonitoring relays are used in all areas of electrical switchgear technology.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":39554979463232,"sku":"3RU2136-4HB0","price":2421.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2136-4HB0.jpg?v=1743420283"},{"product_id":"siemens-sirius-soft-starter-s0-24vac-dc-11kw-25a","title":"Siemens Sirius Soft starter S0, 24VAC\/DC, 11kW, 25A","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS soft starter S0 25 A, 11 kW\/400 V, 40 °C 200-480 V AC, 24 V AC\/DC Screw terminals. This high-performance soft starter provides smooth motor acceleration and deceleration with higher current capacity, reducing mechanical stress and electrical surge currents for enhanced system reliability and energy efficiency in demanding industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3RW4026-1BB04\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eCurrent rating: 25 A\u003c\/li\u003e\n\u003cli\u003ePower rating: 11 kW at 400 V\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 40°C\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 200-480 V AC\u003c\/li\u003e\n\u003cli\u003eControl voltage: 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eTerminal type: Screw terminals\u003c\/li\u003e\n\u003cli\u003eSize: S0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Control Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eSoft start capability for smooth motor acceleration\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eThermal overload protection\u003c\/li\u003e\n\u003cli\u003eReduced starting currents\u003c\/li\u003e\n\u003cli\u003eMechanical stress reduction\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Properties:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eNet weight: 0.708 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 65.00 x 155.00 x 185.00 mm\u003c\/li\u003e\n\u003cli\u003ePackaging quantity: 1 piece\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Czech Republic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eEAN: 4011209691643\u003c\/li\u003e\n\u003cli\u003eUPC: 754554958576\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.07.2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back Obligation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Contains lead, lead monoxide, 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one, and 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol in concentrations higher than 0.1% weight by weight. Based on current information, these substances do not pose risk when used as intended.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClassifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass:\u003c\/strong\u003e 27-37-09-07\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM:\u003c\/strong\u003e EC000640\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUNSPSC:\u003c\/strong\u003e 39-12-15-21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RW4026-1BB04\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/siemens.partcommunity.com\/3d-cad-models\/?languageIso=en\u0026amp;countryIso=US\"\u003e3D CAD Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RW4026-1BB04\"\u003eProduct Details - Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413488447552,"sku":"3RW4026-1BB04","price":6975.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RW4026-1BB04.jpg?v=1726651632"},{"product_id":"siemens-separate-actuator-with-vertical-fixing","title":"Siemens Separate actuator, with vertical fixing","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eSeparate actuator with vertical fixing for position switch with tumbler 3SE5312\/3SE5322 and AS-i 3SF13, and position switch with separate actuator 3SE51\/3SE52 and AS-i 3SF11\/3SF12. This professional-grade coded actuator provides reliable safety interlock functionality with vertical mounting configuration, designed for position sensing of machine parts and position monitoring of protection equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3SE5000-0AV02\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eActuator type: Separate actuator with vertical fixing\u003c\/li\u003e\n\u003cli\u003eCompatibility: 3SE5312\/3SE5322 with tumbler, AS-i 3SF13\u003c\/li\u003e\n\u003cli\u003eAdditional compatibility: 3SE51\/3SE52 separate actuator, AS-i 3SF11\/3SF12\u003c\/li\u003e\n\u003cli\u003eMounting type: Vertical fixing with threaded mount\u003c\/li\u003e\n\u003cli\u003eLength: 53mm\u003c\/li\u003e\n\u003cli\u003eCoded key functionality: Yes\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -25°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eVertical fixing configuration for space-efficient mounting\u003c\/li\u003e\n\u003cli\u003eCoded key design for enhanced security\u003c\/li\u003e\n\u003cli\u003eThreaded mounting system for secure installation\u003c\/li\u003e\n\u003cli\u003eLED status indication capability\u003c\/li\u003e\n\u003cli\u003eQuick-connect technology for reduced connection time\u003c\/li\u003e\n\u003cli\u003eModular design for versatile applications\u003c\/li\u003e\n\u003cli\u003eMultiple mechanical coding to prevent tampering\u003c\/li\u003e\n\u003cli\u003eCompatible with plant and building automation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Areas:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eSafety position switches\u003c\/li\u003e\n\u003cli\u003eInterlock circuit applications\u003c\/li\u003e\n\u003cli\u003ePosition sensing of machine parts\u003c\/li\u003e\n\u003cli\u003ePosition monitoring of protection equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems\u003c\/li\u003e\n\u003cli\u003ePlant and building automation systems\u003c\/li\u003e\n\u003cli\u003eMachine safety circuits\u003c\/li\u003e\n\u003cli\u003eEquipment protection monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Properties:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eNet weight: 0.064 kg\u003c\/li\u003e\n\u003cli\u003eHeight: 58 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 53 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 18 mm\u003c\/li\u003e\n\u003cli\u003eLength: 53 mm\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 55.00 x 58.00 x 21.00 mm\u003c\/li\u003e\n\u003cli\u003ePackaging quantity: 1 piece\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eEAN: 4011209691117\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.07.2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back Obligation:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e No substances of very high concern identified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eEN 50047 compliant\u003c\/li\u003e\n\u003cli\u003eEN 50041 compliant\u003c\/li\u003e\n\u003cli\u003eIEC certified\u003c\/li\u003e\n\u003cli\u003eUL certified\u003c\/li\u003e\n\u003cli\u003eCSA certified\u003c\/li\u003e\n\u003cli\u003eCE marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3SE5000-0AV02\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3SE5000-0AV02\"\u003e3D CAD Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3SE5000-0AV02\"\u003eProduct Details - Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413488414784,"sku":"3SE5000-0AV02","price":140.4,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3SE5000-0AV02.jpg?v=1726651633"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-33a","title":"Siemens Circuit breaker for motor protection, size S00, 33A","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1CA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 1.8 to 2.5 A and N-release rated at 33 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 1.8 to 2.5 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 33 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.765 lb (0.347 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 2.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 0.75 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 0.4 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1CA10 is suitable for protecting medium to larger three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 1.8-2.5 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 0.75 kW at 400V and 0.4 kW at 230V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 33 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.765 lb (0.347 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712430\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643921885\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate-Proof Design:\u003c\/strong\u003e Optimized for use in various environmental conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/?mlfb=3RV2011-1CA10\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413488250944,"sku":"3RV2011-1CA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2011-1CA10.jpg?v=1726499051"},{"product_id":"siemens-circuit-breaker-for-motor-protection-size-s00-65a","title":"Siemens Circuit breaker for motor protection, size S00, 65A","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1FA10 circuit breaker is designed for motor protection in size S00 applications, featuring CLASS 10 A-release protection with an adjustable current range of 3.5 to 5 A and N-release rated at 65 A. This SIRIUS 3RV2 motor starter protector provides comprehensive overload and short-circuit protection for three-phase motors and electrical loads, incorporating screw terminal connections and standard switching capacity for reliable industrial motor control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 3.5 to 5 A adjustable overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e CLASS 10 tripping characteristic according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S00 (45mm width) for compact installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 65 A (N-release) factory-set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw terminals with M3 combination screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection:\u003c\/strong\u003e Built-in phase loss sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Rotary operating mechanism with integrated locking device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Function:\u003c\/strong\u003e Built-in test slide for overload release verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C with temperature compensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail or screw mounting options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.767 lb (0.348 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Advanced SIRIUS 3RV2 generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC (480V UL rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-pole configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.8-1.2 Nm for screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section:\u003c\/strong\u003e 2 x (0.75...2.5) mm² maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e Up to 100 kA short-circuit breaking capacity at 400 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Altitude:\u003c\/strong\u003e Up to 2,000 m above sea level\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20 front face\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw-type with up to two different conductor cross-sections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e IEC 60947-1, IEC 60947-2, IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockout Capability:\u003c\/strong\u003e Padlock shackle diameter 3.5-4.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Switch Compatible:\u003c\/strong\u003e Supports lateral and transverse auxiliary switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Permanent Current (Iu):\u003c\/strong\u003e 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 400V):\u003c\/strong\u003e 1.5 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operation Power (AC-3, 230V):\u003c\/strong\u003e 1.1 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Protection Range:\u003c\/strong\u003e Up to 45 kW at 400 VAC (system capability)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Time:\u003c\/strong\u003e 10 seconds or less at rated current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch-off Technique:\u003c\/strong\u003e Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Yes, with bimetallic heating elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 97 mm H x 45 mm W x 97 mm D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3RV2011-1FA10 is suitable for protecting larger three-phase motors and electrical loads in industrial automation applications where reliable overload and short-circuit protection is required for motor currents between 3.5-5 A. It provides inverse time-delayed protection against overload conditions and instantaneous protection against short-circuits, making it ideal for motor drives, instrumentation systems, automation equipment, precision machinery, conveyor systems, pump panels, mass production lines, HVAC installations, and SIRIUS modular system integration requiring size S00 protection for motors up to 1.5 kW at 400V in demanding industrial environments where higher current protection is essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen an overload occurs, the motor current rises above the set rated current, heating the integrated bimetal element and causing the device to trip through thermal-magnetic operation. For short-circuit conditions, the electromagnetic release provides instantaneous protection at 65 A. The rotary operating mechanism allows manual on\/off operation with clear position indication and trip status display. The adjustment dial enables precise setting to motor FLA (Full Load Amperage). The built-in test function enables verification of overload release operation without electrical load. The device features phase loss sensitivity for enhanced motor protection and provides over-current protection for both AC and DC motors up to 5 AMPS. After tripping, the device must be manually reset by moving the rotary switch to OFF position before reclosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.767 lb (0.348 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 1.929 x 4.016 x 4.016 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209712461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 662643923971\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Standard product, returnable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Yes (since 10\/01\/2009)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Rating:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back:\u003c\/strong\u003e Yes (2012\/19\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains lead in concentrations higher than 0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Control:\u003c\/strong\u003e AL: N \/ ECCN: N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Standards:\u003c\/strong\u003e IEC 60947-1, EN 60947-1, IEC 60947-2, EN 60947-2, IEC 60947-4-1, EN 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Approval:\u003c\/strong\u003e Type E Self Protected Combination Motor Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Short Circuit Breaking Capacity:\u003c\/strong\u003e 65kA at 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClimate-Proof Design:\u003c\/strong\u003e Optimized for use in various environmental conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eCAx Data \u0026amp; 3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eEquipment Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eCircuit Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\" class=\"underline\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2011-1FA10\" class=\"underline\"\u003eSiemens Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413488218176,"sku":"3RV2011-1FA10","price":1323.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2011-1FA10.jpg?v=1726499053"},{"product_id":"siemens-auxiliary-switch-transverse-screw-terminal-2-no","title":"Siemens Auxiliary switch transverse, screw terminal, 2 NO","description":"\u003cp\u003eAuxiliary switch transverse 2 NO, screw terminal for circuit breaker 3RV2 Simple, efficient and always up to date - SIRIUS modular system.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413487824960,"sku":"3RV2901-1F","price":194.4,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2901-1F.jpg?v=1743600449"},{"product_id":"siemens-overload-relay-for-motor-protection-size-s0-11-16a","title":"Siemens Overload relay for motor protection, size S0, 11-16A","description":"\u003cp\u003eOverload relay 11...16 A Thermal For motor protection Size S0, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset thermal overload relay SIRIUS 3RU2 for inverse-time delayed protection of loads with normal starting against excessive temperature rises due to overload or phase failure. This series is particularly flexible and cost-effective. Worldwide approvals (e.g. IEC and UL\/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Can be supplied with different setting ranges of the overload release. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, as well as for stand-alone installation. The accessories consistently fit all sizes from S00 to S3. Simple, efficient and always up to date - SIRIUS modular system.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413486481472,"sku":"3RU2126-4AB0","price":1035.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2126-4AB0.jpg?v=1743600514"},{"product_id":"siemens-solid-state-contactor-1-phase-48-460v","title":"Siemens Solid-state contactor 1-phase, 48 - 460V","description":"\u003ch3\u003eSolid-state Contactor\u003c\/h3\u003e\n\u003cp\u003eThe solid-state contactor is designed for efficient and reliable switching of resistive\/inductive loads in various applications.\u003c\/p\u003e\n\u003ch4\u003eTechnical details:\u003c\/h4\u003e\n\u003cul\u003e\n    \u003cli\u003ePhase-out type: solid-state contactor\u003c\/li\u003e\n    \u003cli\u003e1-phase\u003c\/li\u003e\n    \u003cli\u003e3RF2\u003c\/li\u003e\n    \u003cli\u003eAC 15 \/ 12 A \/ 40 °C\u003c\/li\u003e\n    \u003cli\u003e48-460 V \/ 4-30 V DC\u003c\/li\u003e\n    \u003cli\u003eInstantaneous switching for switching resistive\/inductive loads\u003c\/li\u003e\n    \u003cli\u003eIntegrated heat sink for direct use in control cabinet\u003c\/li\u003e\n    \u003cli\u003eCompact design saves space on the DIN rail\u003c\/li\u003e\n    \u003cli\u003eApproval for worldwide use (e.g. IEC and UL\/CSA)\u003c\/li\u003e\n    \u003cli\u003eAvailable as single-phase or three-phase devices\u003c\/li\u003e\n    \u003cli\u003eDesigned for AC or DC operation\u003c\/li\u003e\n    \u003cli\u003eAvailable with screw, spring-type or ring terminal lug connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCustomer benefits:\u003c\/h4\u003e\n\u003cul\u003e\n    \u003cli\u003eNon-wearing and silent, ideal for noise-sensitive areas (offices, hospitals)\u003c\/li\u003e\n    \u003cli\u003eExtremely reliable at high switching frequencies\u003c\/li\u003e\n    \u003cli\u003eCan be expanded for a wide range of applications with standardized 3RF29 function modules\u003c\/li\u003e\n    \u003cli\u003eAccessories available: control connectors and terminal covers\u003c\/li\u003e\n    \u003cli\u003ePart of the simple, efficient, and always up-to-date SIRIUS modular system\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413485596736,"sku":"3RF2320-1BA44","price":2196.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RF2320-1BA44.jpg?v=1726651645"},{"product_id":"siemens-stand-alone-assembly-support-size-s00","title":"Siemens Stand-alone assembly support, size S00","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003eProduct Overview\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number: 3RU2136-4JB0\u003c\/strong\u003e - SIRIUS 3RU2136-4JB0 thermal overload relay for mounting on Sirius 3RT203 size S2 contactors (3RT2037 and 3RT2038) and is adjustable from 54A-65A. This Class 10 overload (trips in 10 seconds or less) has phase loss protection, manual or automatic reset and two auxiliary contacts, one normally open and one normally closed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eCurrent setting range: 54-65 A\u003c\/li\u003e\n\u003cli\u003eFrame size: S2\u003c\/li\u003e\n\u003cli\u003eTrip class: CLASS 10\u003c\/li\u003e\n\u003cli\u003ePhase failure protection: Yes\u003c\/li\u003e\n\u003cli\u003eReset options: Manual\/Automatic\u003c\/li\u003e\n\u003cli\u003eAuxiliary contacts: 1 NO + 1 NC\u003c\/li\u003e\n\u003cli\u003eMain circuit connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eAuxiliary circuit connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 0.34 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003ePhase loss protection for the purpose of minimizing the heating of the load during single-phase operation as a result of phase failure\u003c\/li\u003e\n\u003cli\u003eSwitch position indicator and TEST function\u003c\/li\u003e\n\u003cli\u003eSTOP button for emergency disconnection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation according to IEC 60947-4-1\/DIN VDE 0660 Part 102\u003c\/li\u003e\n\u003cli\u003eManual and automatic reset functionality\u003c\/li\u003e\n\u003cli\u003eSealable transparent cover (optional accessory)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Designed for thermal overload protection of three-phase and single-phase AC and DC motors. The 3RU2136 thermal overload relays are suitable for direct mounting on the 3RT203 contactors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eAmbient temperature: -20°C to +60°C (with temperature compensation)\u003c\/li\u003e\n\u003cli\u003eTrip characteristics: Inverse time-delayed according to CLASS 10\u003c\/li\u003e\n\u003cli\u003eIt is possible to switch between manual resetting and automatic resetting by depressing and rotating the blue button (RESET button).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Direct mounting on Size S2 contactors (3RT2037, 3RT2038) or stand-alone installation with terminal bracket accessory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eIEC 60947-1\/DIN VDE 0660 Part 100\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1\/DIN VDE 0660 Part 102\u003c\/li\u003e\n\u003cli\u003eIEC 60947-5-1\/DIN VDE 0660 Part 200\u003c\/li\u003e\n\u003cli\u003eUL 508\/CSA C 22.2\u003c\/li\u003e\n\u003cli\u003eEEx e increased safety type protection certification available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Properties:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eNet Weight: 0.344 kg\u003c\/li\u003e\n\u003cli\u003ePackaging Dimension: 61.00 x 96.00 x 111.00 mm\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003eDownload existing graphical data for this product:\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/830\/35681830\/att_96300\/v1\/lv1t_052_en_2011_04.pdf\"\u003eTechnical Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/60298164\/equipment-manual-sirius-3ru-thermal-overload-relays-3rb-electronic-overload-relays\"\u003eEquipment Manual - SIRIUS 3RU Thermal Overload Relays\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/assets.new.siemens.com\/siemens\/assets\/api\/uuid:db98727f-1c3d-43cb-ab6e-2055705305b4\/version:1557325577\/ic17-sect-03-rev031519.pdf\"\u003eOverload Relays Catalog Section\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/ww\/en\/view\/20357046\/133200\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413485563968,"sku":"3RU2916-3AA01","price":200.7,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RU2916-3AA01.jpg?v=1743600553"},{"product_id":"siemens-analog-monitoring-relay-screw-160-690v","title":"Siemens Analog monitoring relay, screw, 160 - 690V","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdvanced analog monitoring relay designed for comprehensive three-phase power system protection, featuring phase failure and sequence monitoring with adjustable undervoltage detection capabilities. This SIRIUS 3UG4 series monitoring relay provides multi-functional protection including phase sequence verification, phase failure detection, and customizable undervoltage monitoring across a wide voltage range of 160-690 V AC. The device incorporates fixed 20% asymmetry detection and dual changeover contacts for enhanced system reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eMulti-functional monitoring: phase failure, sequence, and adjustable undervoltage\u003c\/li\u003e\n\u003cli\u003eWide voltage range: 160-690 V AC for international compatibility\u003c\/li\u003e\n\u003cli\u003eFixed asymmetry detection at 20% threshold for unbalanced load protection\u003c\/li\u003e\n\u003cli\u003eAdjustable undervoltage monitoring with customizable threshold settings\u003c\/li\u003e\n\u003cli\u003eFixed 5% hysteresis for stable operation and contact chatter prevention\u003c\/li\u003e\n\u003cli\u003eAdjustable delay time: 0-20 seconds for application-specific timing requirements\u003c\/li\u003e\n\u003cli\u003eDual changeover contacts (2 SPDT) for comprehensive control capabilities\u003c\/li\u003e\n\u003cli\u003eSelf-powered operation without auxiliary voltage requirement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3UG4513-1BR20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Functions:\u003c\/strong\u003e Phase failure, phase sequence, adjustable undervoltage, asymmetry detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage Range:\u003c\/strong\u003e 3 x 160...690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 50...60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsymmetry Detection:\u003c\/strong\u003e 20% fixed threshold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis:\u003c\/strong\u003e 5% fixed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelay Time Range:\u003c\/strong\u003e 0-20 seconds (adjustable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e 2 changeover contacts (2 SPDT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminal with removable terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22.5mm (W) x 92mm (H) x 91mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.145 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209642263\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Use Cases\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eMobile system protection (A\/C compressors, refrigerated containers)\u003c\/li\u003e\n\u003cli\u003eConstruction site equipment monitoring (compressors, cranes)\u003c\/li\u003e\n\u003cli\u003eCritical industrial motor protection requiring voltage stability\u003c\/li\u003e\n\u003cli\u003eThree-phase power distribution systems with voltage quality requirements\u003c\/li\u003e\n\u003cli\u003eInternational installations requiring wide voltage compatibility\u003c\/li\u003e\n\u003cli\u003eApplications requiring both phase monitoring and undervoltage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Monitoring Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Sequence Detection:\u003c\/strong\u003e Verifies correct L1-L2-L3 rotation order\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Failure Detection:\u003c\/strong\u003e Immediate detection of any phase loss condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Undervoltage Monitoring:\u003c\/strong\u003e Customizable threshold for voltage drop protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Asymmetry Detection:\u003c\/strong\u003e 20% threshold for unbalanced phase protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis Control:\u003c\/strong\u003e 5% fixed hysteresis prevents contact chatter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiming Control:\u003c\/strong\u003e Adjustable 0-20 second delay prevents nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Contact Output:\u003c\/strong\u003e Two independent changeover contacts for complex control schemes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign \u0026amp; Installation Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eSlim profile design (22.5mm width) optimizes control cabinet space\u003c\/li\u003e\n\u003cli\u003eRemovable screw terminals facilitate pre-wiring and maintenance\u003c\/li\u003e\n\u003cli\u003eSelf-powered operation eliminates need for auxiliary supply\u003c\/li\u003e\n\u003cli\u003eWide voltage range accommodates various international power standards\u003c\/li\u003e\n\u003cli\u003eClosed-circuit principle ensures fail-safe operation\u003c\/li\u003e\n\u003cli\u003eAnalog adjustment capabilities for precise threshold setting\u003c\/li\u003e\n\u003cli\u003eSnap-on mounting for quick installation and replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Level Protection:\u003c\/strong\u003e Combined phase, sequence, and voltage monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Adjustment:\u003c\/strong\u003e Customizable voltage drop threshold setting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Asymmetry Protection:\u003c\/strong\u003e 20% unbalance detection prevents motor damage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTiming Flexibility:\u003c\/strong\u003e 0-20 second delay range accommodates various applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Output Capability:\u003c\/strong\u003e Two changeover contacts for comprehensive control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Certification:\u003c\/strong\u003e Worldwide use approval for global deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.05.2012\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back Obligation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Contains Lead, Lead monoxide (lead oxide), and 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol in concentrations higher than 0.1% weight by weight. These substances do not pose risk when used as intended.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClassification Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass 14:\u003c\/strong\u003e 27-37-18-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass 12:\u003c\/strong\u003e 27-37-18-03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM 9:\u003c\/strong\u003e EC001441\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUNSPSC 15:\u003c\/strong\u003e 39-12-15-21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3UG4513-1BR20\"\u003eProduct Datasheet\u003c\/a\u003e - Technical specifications and connection diagrams\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/54397927\/equipment-manual-sirius-3ug4-3rr2-monitoring-relays\"\u003eEquipment Manual - SIRIUS 3UG4 \/ 3RR2 Monitoring Relays\u003c\/a\u003e - Comprehensive installation and operation guide\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/attachments\/54397927\/manual_monitoring_relay_3UG4_3RR2_en-US.pdf\"\u003eSIRIUS 3UG4 \/ 3RR2 Manual\u003c\/a\u003e - Complete technical documentation and wiring diagrams\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/document\/22114101\/sirius-monitoring-relays-for-single-phase-current-monitoring\"\u003eSIRIUS Monitoring Relay Application Guide\u003c\/a\u003e - Application examples and configuration guidelines\u003c\/li\u003e\n\u003cli\u003e\n\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3UG45131BR20\/phase-failure-and-sequence\"\u003eProduct Support Page\u003c\/a\u003e - Additional technical resources and troubleshooting information\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413483565120,"sku":"3UG4513-1BR20","price":1768.44,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3UG4513-1BR20.jpg?v=1743600667"},{"product_id":"siemens-circuit-breaker-for-system-protection-size-s00","title":"Siemens Circuit breaker for system protection, size S00","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SIRIUS 3RV2 circuit breaker is a compact, climate-resistant device designed for system protection with full UL 489 and CSA C22.2 No. 5-02 approval. This frame size S00 circuit breaker features thermal overload release at 3.2A and short-circuit release at 42A with screw terminal connections and standard switching capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis circuit breaker is optimized for system protection according to UL 489\/CSA C22.2 No. 5 standards for short-circuit protection of systems and loads in UL-configured plants. With low heat loss design, it's ideal for use in load feeders, IE3\/IE4 motors, and direct current switching applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e S00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Overload Release:\u003c\/strong\u003e 3.2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Release:\u003c\/strong\u003e 42A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Short-Circuit Breaking Capacity:\u003c\/strong\u003e 100kA at 400V, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e Up to 690V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Element:\u003c\/strong\u003e Toggle switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.497kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 55 x 191 x 110mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 489:\u003c\/strong\u003e Circuit breaker approval for system protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 5-02:\u003c\/strong\u003e Canadian standards approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Standards:\u003c\/strong\u003e International electrotechnical compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IEC Ex:\u003c\/strong\u003e Hazardous area applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign \u0026amp; Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures compact design with climate-resistant construction optimized for low heat loss operation. The device includes screw-type terminals for secure connections and toggle control element for reliable operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis circuit breaker is designed for system protection in industrial applications, including:\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eShort-circuit protection of systems and loads in UL-configured plants\u003c\/li\u003e\n\u003cli\u003eLoad feeder protection\u003c\/li\u003e\n\u003cli\u003eIE3\/IE4 motor applications\u003c\/li\u003e\n\u003cli\u003eDirect current switching\u003c\/li\u003e\n\u003cli\u003ePlant protection applications\u003c\/li\u003e\n\u003cli\u003eStarter combination short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail mounting capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Fixed installation technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Configuration:\u003c\/strong\u003e Screw terminals for main circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contacts:\u003c\/strong\u003e No auxiliary contacts included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 4011209767591\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Contains lead in concentrations \u0026gt;0.1% w\/w\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A: Standard stock item\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device is designed for industrial environments and includes environmental product declarations. It meets WEEE take-back obligations and complies with RoHS substance restrictions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RV2711-1DD10\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/cs\/products\/3RV2711-1DD10\/circuit-breaker-ul489-3-2a?pid=38992\u0026amp;dtp=\u0026amp;mlfb=3RV2711-1DD10\u0026amp;lc=en-WW\"\u003eCAD Models and Technical Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2711-1DD10\"\u003eProduct Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Product\/3RV2711-1DD10\"\u003eEnvironmental Product Declaration\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"h-8\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413483106368,"sku":"3RV2711-1DD10","price":2826.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2711-1DD10.jpg?v=1726651650"},{"product_id":"siemens-circuit-breaker-size-s0-for-motor-protection","title":"Siemens Circuit breaker size S0 for motor protection","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003ch1 class=\"text-2xl font-bold mt-1 text-text-100\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eCircuit breaker size S0 for motor protection, CLASS 10 A-release 10...16 A N-release 208 A screw terminal Standard switching capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e S0 (45 mm width)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e 10...16 A adjustable thermal overload release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit Release:\u003c\/strong\u003e 208 A (N-release)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Class:\u003c\/strong\u003e CLASS 10 according to IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection System:\u003c\/strong\u003e Screw terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e Standard switching capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eIEC 60947-1, EN 60947-1 (VDE 0660 Part 100)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2, EN 60947-2 (VDE 0660 Part 101)\u003c\/li\u003e\n\u003cli\u003eIEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102)\u003c\/li\u003e\n\u003cli\u003eUL 508 (UL 60947-4-1), CSA C22.2 No. 14 (CSA-C22.2 No. 60947-4-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eAmbient Temperature: -20°C to +70°C (with current reduction above +60°C)\u003c\/li\u003e\n\u003cli\u003eMounting Position: Any position according to IEC 60447\u003c\/li\u003e\n\u003cli\u003eDegree of Protection: IP20\u003c\/li\u003e\n\u003cli\u003eTouch Protection: Finger-safe according to DIN EN 50274\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.364 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003ePhase loss sensitivity for reliable motor protection\u003c\/li\u003e\n\u003cli\u003eIntegrated overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eTemperature compensation from -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eTest function for operational verification\u003c\/li\u003e\n\u003cli\u003eIsolating function according to IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eExplosion protection approval for motors with \"increased safety\" type (EEx e)\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity up to 55 kA at 400V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eMotor protection for three-phase motors (10-18.5 HP range)\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection for high-power applications\u003c\/li\u003e\n\u003cli\u003eSystem protection applications\u003c\/li\u003e\n\u003cli\u003eLoad feeder protection\u003c\/li\u003e\n\u003cli\u003eControl circuit switching\u003c\/li\u003e\n\u003cli\u003eSuitable for motors with rated currents between 10-16 A\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control applications\u003c\/li\u003e\n\u003cli\u003eManufacturing and production line equipment\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial applications\u003c\/li\u003e\n\u003cli\u003eLarge conveyor systems and industrial machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eConnection System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eConnection Screw: M4, Pozidriv size 2\u003c\/li\u003e\n\u003cli\u003eOperating Tool: Ø 5 to 6 mm\u003c\/li\u003e\n\u003cli\u003eSpecified Tightening Torque: 2.0 to 2.5 Nm\u003c\/li\u003e\n\u003cli\u003eConductor Cross-sections (1-wire or 2-wire connection possible):\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eSolid and stranded: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 10) mm²\u003c\/li\u003e\n\u003cli\u003eFinely stranded with end sleeve: 2 x (1.0 to 2.5) mm², 2 x (2.5 to 6) mm², max. 1 x 10 mm²\u003c\/li\u003e\n\u003cli\u003eAWG cables: 2 x (16 to 12), 2 x (14 to 8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAccessories Available\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eAuxiliary switches (transverse and lateral)\u003c\/li\u003e\n\u003cli\u003eSignaling switches for status monitoring\u003c\/li\u003e\n\u003cli\u003eAuxiliary releases (undervoltage and shunt)\u003c\/li\u003e\n\u003cli\u003eDisconnector modules\u003c\/li\u003e\n\u003cli\u003eDoor-coupling rotary operating mechanisms\u003c\/li\u003e\n\u003cli\u003eEnclosures and mounting accessories\u003c\/li\u003e\n\u003cli\u003eLink modules for contactor integration\u003c\/li\u003e\n\u003cli\u003e3-phase busbar systems\u003c\/li\u003e\n\u003cli\u003eSealable covers for tamper protection\u003c\/li\u003e\n\u003cli\u003ePhase barriers for enhanced safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eMounting: 35 mm DIN rail according to DIN EN 60715 or screw mounting\u003c\/li\u003e\n\u003cli\u003eClearance Requirements: 30 mm from grounded or live parts\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminals for secure and reliable wiring\u003c\/li\u003e\n\u003cli\u003eModular System: Compatible with SIRIUS 3RT2 contactors and accessories\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions: 49.00 x 102.00 x 102.00 mm\u003c\/li\u003e\n\u003cli\u003eSnap-on mounting for easy installation and removal\u003c\/li\u003e\n\u003cli\u003eSide-by-side mounting capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Take-back obligation applies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Regularly screened for Substances of Very High Concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL\/CSA Approvals:\u003c\/strong\u003e Available for North American applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Approval:\u003c\/strong\u003e For hazardous area applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e A - Standard product, stock item with return guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eQuality \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eManufactured in Germany with strict quality control\u003c\/li\u003e\n\u003cli\u003eLong-term stability with proven bimetal technology\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 100,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eMaximum switching frequency: 15 starts per hour\u003c\/li\u003e\n\u003cli\u003eCurrent-limiting characteristics for enhanced protection\u003c\/li\u003e\n\u003cli\u003eVibration and shock resistance according to IEC 60068-2-27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eMotor Protection Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003ePrevents motor damage from overload conditions\u003c\/li\u003e\n\u003cli\u003eProtects against phase loss and unbalanced loads\u003c\/li\u003e\n\u003cli\u003eReduces downtime with reliable trip characteristics\u003c\/li\u003e\n\u003cli\u003eExtends motor life through precise current monitoring\u003c\/li\u003e\n\u003cli\u003eSuitable for standard and energy-efficient IE3 motors\u003c\/li\u003e\n\u003cli\u003eOptimized for side-by-side installation in control panels\u003c\/li\u003e\n\u003cli\u003eHigh N-release rating (208A) for demanding high-power applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDesign Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eRobust screw terminal design for industrial environments\u003c\/li\u003e\n\u003cli\u003eClear current setting scale for easy adjustment (10-16A range)\u003c\/li\u003e\n\u003cli\u003eIntegrated test function for maintenance verification\u003c\/li\u003e\n\u003cli\u003eCompact 45mm width for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eLockable rotary operating mechanism\u003c\/li\u003e\n\u003cli\u003eVisual trip indication for quick fault identification\u003c\/li\u003e\n\u003cli\u003eEnhanced short-circuit protection with 208A N-release\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eHigh-Power Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eDesigned for larger industrial motors and equipment\u003c\/li\u003e\n\u003cli\u003eSuperior short-circuit protection with 208A N-release\u003c\/li\u003e\n\u003cli\u003eIdeal for applications requiring higher current ratings\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous operation in demanding environments\u003c\/li\u003e\n\u003cli\u003eOptimized for IE3 energy-efficient motors\u003c\/li\u003e\n\u003cli\u003eEnhanced protection for high-value industrial equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003eDimension Drawings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003eWiring Diagrams\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003eCAD Data\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003e3D Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/cache.industry.siemens.com\/dl\/files\/172\/60279172\/att_71569\/v1\/manual_SIRIUS_Innovations_circuit_breaker_3RV2_en-US.pdf\"\u003eProduct Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/configurators\"\u003eConfiguration Tool\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.automation.siemens.com\/WW\/view\/en\/3RV2021-4AA10\"\u003eProduct Support Portal\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl font-bold text-text-100 mt-1 -mb-0.5\"\u003e\u003cstrong\u003eAdditional Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/manuals\"\u003eSIRIUS System Overview\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/technical-assistance\"\u003eTechnical Assistance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/training\"\u003eOnline Training\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/www.siemens.com\/sirius\/mall\"\u003eIndustry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/WW\/Catalog\/Products\/10047435?activeTab=product\"\u003eSIRIUS 3RV2 Motor Starter Protectors\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"h-8\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413482713152,"sku":"3RV2021-4AA10","price":1611.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2021-4AA10.jpg?v=1726499107"},{"product_id":"siemens-busbar-3-phase-with-infeed-left-for-2-cbs","title":"Siemens Busbar, 3-phase with infeed left for 2 CB's","description":"\u003cdiv class=\"grid-cols-1 grid gap-2.5 [\u0026amp;_\u0026gt;_*]:min-w-0 !gap-3.5\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3-phase busbar with infeed left for 2 circuit breakers Size S00 and S0. This infeed system component provides efficient power distribution and connection for multiple circuit breakers in electrical control panels, ensuring reliable power supply organization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 3RV2917-1A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eConfiguration: 3-phase busbar\u003c\/li\u003e\n\u003cli\u003eInfeed position: Left side\u003c\/li\u003e\n\u003cli\u003eCompatibility: 2 circuit breakers Size S00 and S0\u003c\/li\u003e\n\u003cli\u003eApplication: 3RV2 series circuit breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Properties:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eNet weight: 0.417 kg\u003c\/li\u003e\n\u003cli\u003ePackaging dimensions: 93.00 x 117.00 x 149.00 mm\u003c\/li\u003e\n\u003cli\u003ePackaging quantity: 1 piece\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Czech Republic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Identifiers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003eEAN: 4011209719125\u003c\/li\u003e\n\u003cli\u003eUPC: 662643925098\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance \u0026amp; Environmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Since 01.10.2009\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Take-Back Obligation:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Currently no information on SVHC (Substances of Very High Concern) from the supply chain. Products are regularly compared with candidate list requirements according to REACH regulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eClassifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eeClass:\u003c\/strong\u003e 27-37-03-92\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETIM:\u003c\/strong\u003e EC001531\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUNSPSC:\u003c\/strong\u003e 39-12-14-32\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownload existing graphical data for this product:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc space-y-1.5 pl-7\"\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/support.industry.siemens.com\/teddatasheet\/?format=pdf\u0026amp;mlfbs=3RV2917-1A\u0026amp;language=en\u0026amp;caller=SIOS\"\u003eTechnical Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/siemens.partcommunity.com\/3d-cad-models\/?languageIso=en\u0026amp;countryIso=US\"\u003e3D CAD Models\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"underline\" href=\"https:\/\/mall.industry.siemens.com\/mall\/en\/ww\/Catalog\/Product\/3RV2917-1A\"\u003eProduct Details - Industry Mall\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":40413482319936,"sku":"3RV2917-1A","price":413.1,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/files\/3RV2917-1A.jpg?v=1743600741"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/3662\/3424\/collections\/8WD4400-1AB.jpg?v=1788788200","url":"https:\/\/industrial.rubicon.tech\/collections\/siemens-sirius.oembed?page=6","provider":"Rubicon Group Industrial Technology Shop","version":"1.0","type":"link"}